CIRCUIT DESCRIPTION
12-11) OPTION Circuit
●
This circuit operates with the initial power on, uses DIODE (1N4148) or JUMPER WIRE.
To modify option circuit, Power must be turned off before modification and turned on after the modification.
Refer to the table below, the default factory values are highly recommended unless exceptional cases.
OP11, OP12
OP11
○
○
●
*
Jumper USE OP2
●
*
Water Fill Time Cantrol Option
●
D601
●
●
○
○
*
Diode(1N4148) USE
●
OP12
MODEL
RS2 * 11
○
RS2 * 21
●
RS2 * 31
○
D602
Fill Time
●
5 Sec
6 Sec
○
●
7 Sec
○
10 Sec
93
FUNTION
No Cruch, 3 Step, Light
Cruch, 3 Step, Light
Cruch, 5 Step, P/F, L/T Lock, Filter, Indicator
Remark
Flow Sensor Not USE