Honeywell NS1 Installation Manual page 5

Advertisement

3. Set Open Time-out (11*).
Whenever access is granted, the relay of the NS1 will be activated during a certain number of
seconds, called the Open Time-Out.
This period of time can be adjusted from 1 to 255 seconds. The default value is 2 sec, meaning
that after presenting the tag to the NS1 reader, you have 2 seconds to open the door. If you want
to use the default value, skip this step and proceed with the next.
To use a setting other than the default one, perform the steps indicated in Figure 5.
1. Enter Program Mode by
presenting Installer Remote
Programmer.
Figure 5
Setting Open Time-out Period
4. Set Close Time-out (12*).
The NS1 has a special timer that is intended to check whether the gate or door has been closed
within a specific period of time.
This period of time is adjustable from 0 to 255 seconds. The default value is "0", meaning that the
function is disabled. If you want to use the default value, skip this step and proceed with the next.
I/O 1 of the NS1 should be connected to ground or to ground via the door switch when
using this option.
To use a setting other than the default one, perform the steps indicated in Figure 6.
1. Enter Program mode by
presenting Installer Remote
Programmer.
Figure 6
Setting the Close Time-out Period
TD1166 rev1003
2. Enter Open Time-out period.
2. Enter Close Time-out period.
3. Normal operation of the
NS1 is resumed.
3. Normal operation of the
NS1 is resumed.
5 - 8