Honeywell NS1 Installation Manual page 3

Advertisement

NS1 OPERATING LEVELS
The NS1 Proximity Reader has two operating levels:
Installer Level. On this level the NS1 can be configured by the Installer. This level is also used to do
typical Installer options.
User Level. On this level typical user options can be set, such as adding and voiding user cards,
setting the door open time, etc.
This Quick Guide explains the most frequently used Installer settings that can be used to configure the
NS1. Please refer to the NS1 User Guide (TD1168) for user related settings.
The programming steps mentioned in this Quick Guide represent a limited number of programming
functions that can be performed by the Installer on an NS1. Please refer to the NS1 Master Manual
(TD0099) for all the possibilities.
NS1 LEDS
The NS1 is provided with seven LEDs which serve as status indicators. Figure 2 illustrates their function.
Figure 2
LED indicators NS1
PROGRAMMING DEVICE
A remote programmer can be used to configure the NS1 and do settings in the NS1 by
bringing it into the RF field of the NS1.
1 2 3
A programmed function may look like as follows:
4
5 6
7 8
9
The blank "n" in the function indicates an optional number.
0
#
*
In this Quick Guide, configuring the NS1 Proximity Reader is described by means of a Remote
Programmer. However, there are other ways. Northern also offers the possibility of programming the NS1
Proximity Reader through the NS1 Manage PC software.
If you have to install this application, please refer to the installation instructions of the NS1 Manage
manual (TD0099).
TD1166 rev1003
Led 1 (yellow)
Indicates that a card/remote programmer is within range of the NS1.
Led 2 (green)
Indicates that access is granted or that the NS1 is in Unlock Mode.
Led 3 (red)
Indicates that the door lock is closed.
Led 4 (red)
Indicates that the NS1 is in Night Lock mode.
Led 5 (red)
Indicates that the NS1 is in Add mode, and that cards are added.
Led 6 (red)
Indicates that the NS1 is in Void mode, and that cards are voided.
Led 7 (red)
Indicates that the NS1 is in Program mode.
An Installer Remote Programmer can set all functions of the NS1.
3 - 8