Honeywell GW-1000-WE Installation Instructions Manual

Honeywell GW-1000-WE Installation Instructions Manual

Smb gateway
Hide thumbs Also See for GW-1000-WE:

Advertisement

Quick Links

SMB Gateway
GW-1000-WE/GW-1000-NWE
INSTALLATION INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell GW-1000-WE

  • Page 1 SMB Gateway GW-1000-WE/GW-1000-NWE INSTALLATION INSTRUCTIONS...
  • Page 2 Administrator Supervisor Dashboard (built on purposes only and may not match the actual product. Honeywell Forge cloud platform). • Configurable via the Honeywell Connect Mobile app. • Integrated with Honeywell Thermostat (TC500A-N/ TC500A-W) and Honeywell Smart IO (IO-10MIXR- NWE/IO-10MIXR-WE) via BACnet (secured).
  • Page 3 GATEWAY (GW-1000-WE/GW-1000-NWE) INTERFACES AND TERMINALS NOTE: *All RS485 interfaces, USB interfaces, RJ11 interface, Rx and Tx LEDs are for future use. Table 1. Gateway Terminals Type Legend Signal Comment FGND Connect to earth ground in the field Power Supply 24V0...
  • Page 4 For more information, refer to the Small and Medium Building Administrator Supervisor Dashboard user guide (31- 00379M). Honeywell Connect Mobile App For more information, refer to the Honeywell 2.Small and Medium Business Administrator Setup Guide (Deploy App Setup Guide) (31-00451M). 31-00424 | Rev.10-20...
  • Page 5 GATEWAY (GW-1000-WE/GW-1000-NWE) TECHNICAL DATA Table 5. Standards System The system transformer(s) must be System Data Transformer safety isolating transformers according to IEC 61558-2-6. In the U.S.A. and Canada, NEC Class 2 Table 2. System Data transformers must be used. Operating...
  • Page 6 GATEWAY (GW-1000-WE/GW-1000-NWE) Communication Baud Rates Gateway Parameters Table 7. Communication Baud Rates Table 8. Gateway Parameters Ethernet 10/100/1000 Mbit/s, RJ45 Max number of points 3000 BACnet MSTP 9.6, 19.2, 38.4, 76.8, 115.2 Kbps Max trend retention 2 days (1 min...
  • Page 7 GATEWAY (GW-1000-WE/GW-1000-NWE) Accessories Part Numbers These accessories are available by separate order. Table 10. Accessories Part Number Description Replacement Terminal Covers (Small) GW-TCVR (Pack Quantity of 4) Extended Terminal Covers (Large) GW-EXT-TCVR (Pack Quantity of 4) Remote Antennas with adhesive magnetic foot for wireless communication.
  • Page 8 Standard(s) C22.2, No. 205-M1983 (CNL-listed). warranties concerning operation and safety are • Do not open the GW-1000-WE/GW-1000-NWE, as it invalidated. contains no user-serviceable parts inside! • Make sure that the local standards and regulations are •...
  • Page 9 (both horizontal and vertical rail mounting possible). WEEE The GW-1000-WE/GW-1000-NWE is used for the purpose of building HVAC control and is suitable for use only in non-safety controls for installation on or in appliances. WEEE Directive 2012/19/EC Waste...
  • Page 10: Table Of Contents

    Dimensions ................12 Reset Button .................. 8 GW-1000-WE/GW-1000-NWE Gateway ......12 Communication Baud Rates ........... 8 Connection to Honeywell Forge ..........8 Appendix: Earth Grounding ..........13 Gateway and SELV ................13 Connection to MultiTech LoRaWAN Hub ......8 Gateway and EN60204-1 ............13 Small and Medium Building Functional EMC Grounding ............13...
  • Page 11: General Safety Information

    (both horizontal and vertical rail mounting INFORMATION possible). The GW-1000-WE/GW-1000-NWE gateway is used for the • When performing any work (installation, mounting, purpose of building HVAC control and is suitable for use start-up), all manufacturer instructions and in...
  • Page 12: Technical Data

    GATEWAY (GW-1000-WE/GW-1000-NWE) TECHNICAL DATA Table 5. Operational Environment RFI, EMI Residential, commercial, and Electrical Data light-industrial environments MTBF (Mean Time 11.5 years Table 2. Electrical Data Between Failure) Operating Voltage 19 to 29 Vac (50/60Hz) Default IP Address (AC) Operating Voltage 19 to 29 Vdc Table 6.
  • Page 13: Interfaces

    INTERFACES Fig. 1. GW-1000-WE/GW-1000-NWE Gateway NOTE: *All RS485 interfaces, USB interfaces, RJ11 interface, Rx and Tx LEDs are for future use. Table 8. Gateway Terminals Type Legend Signal Comment FGND Connect to earth ground in the field Power Supply 24V0...
  • Page 14: Main Led

    GATEWAY (GW-1000-WE/GW-1000-NWE) Table 8. Gateway Terminals (Continued) Type Legend Signal Comment *Tx3 LED (green) Transmit and receive indication for RS485 interfaces 1 to 3 *Rx3 LED (green) Main LED Indicates the operational status of the Gateway Dedicated to Internet/Cloud connectivity...
  • Page 15: Ethernet Leds

    Table 9. Main LED Pattern LED behavior Visual Meaning Blink every 0.2S Green Firmware download   or device configuration is in progress Blink every 0.2S Red Total communication failure Three  Blinks in 1.5 Internet/Cloud connection failure second interval and then Pause for 2 sec Red  2 Red Blinks and Pause ...
  • Page 16: Reset Button

    Risk of electric shock or equipment damage! • Retains the current firmware version • Retains the current OS version • Do not connect more than one GW-1000-WE/GW- • LED Yellow breathing 1000-NWE gateways to the same transformer. Communication Baud Rates...
  • Page 17: Switch Mode Power Supply

    Connecting Power Supply General Safety Considerations Connect the power supply to the power supply terminals of • When connecting the GW-1000-WE/GW-1000-NWE the GW-1000-WE/GW-1000-NWE gateway. gateway, VDE, National Electric Code (NEC) or equivalent, and any local regulations concerning The factory default Gateway must be powered ON for a grounding must be observed.
  • Page 18: Wiring Connections

    GATEWAY (GW-1000-WE/GW-1000-NWE) WIRING CONNECTIONS Gateway to MultiTech LoRaWAN hub connection GND_ISO 5V_ISO Isola on Mul Tech LoRaWAN Hub Barrier GW-1000-WE/ GW-1000-NWE WARNING Do not connect the MultiTech LoRaWAN Hub to Ethernet 1 If connected to Ethernet 1 mistakenly, then restart the MultiTech LoRaWAN Hub before connecting to Ethernet 2...
  • Page 19: Wireless Connectivity

    WIRELESS CONNECTIVITY harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does Connectivity Frequency Range cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to Table 16.
  • Page 20: Dimensions

    GATEWAY (GW-1000-WE/GW-1000-NWE) DIMENSIONS GW-1000-WE/GW-1000-NWE Gateway 145.8 mm (5.744") 45 mm 110 mm (1.772") (4.331") 135 mm 52 mm (5.315") (2.047") 59 mm (2.323") 31-00426 | Rev.10-20...
  • Page 21: Appendix: Earth Grounding

    WE/GW-1000-NWE gateway. against electrical impact. 110VAC/230VAC Func on Earth Grounding for EMC To support SELV, all Honeywell external (CRT series) or 24VAC internal transformers comply with standard EN60742. Earth grounding is therefore not recommended. Gateway and EN60204-1 However, if compliance with the standard EN60204-1 is...
  • Page 22: Gateway Part Numbers

    GATEWAY (GW-1000-WE/GW-1000-NWE) GATEWAY PART NUMBERS Table 17. Gateway Part Numbers Part Number Description GW-1000-WE Wireless Gateway with European and Latin American conformance GW-1000-NWE Wireless Gateway with North American conformance Accessories Part Numbers These accessories are available by separate order. Table 18. Accessories...
  • Page 23: Hub And Sensors

    Remote Antenna Part Numbers Table 19. Remote Antenna Part Numbers Antenna Part Number Vendor Name Type Gain CA #ANTT935-4 ADAM External 2.4 GHz: 2.9dbi ANT-DB1-LCD-SMA LINX External 2.4 GHz: 2.8dbi ARY113-0012-004-00 WIESON External 2.4 GHz: -0.31dbi Declaration Transmitter Antenna (From Section 6.8 RSS-GEN, Issue 5, April 2018): —...
  • Page 24 Admin document. Contains Onboarding User Guide procedures to create new organization and User accounts. Honeywell Building Solutions Honeywell International Inc. 715 Peachtree Street NE Atlanta, GA 30308 ® U.S. Registered Trademark customer.honeywell.com © 2020 Honeywell International Inc. 31-00426 | Rev.10-20 buildingcontrols.honeywell.com...

This manual is also suitable for:

Gw-1000-nwe