Appendix; Red Led Behavior And Projector Errors - InFocus IN72 Reference Manual

Hide thumbs Also See for IN72:
Table of Contents

Advertisement

Appendix

Red LED behavior and projector errors

If the projector is not functioning properly and the LED is blinking red, con-
sult Table 4 to determine a possible cause. There are two-second pauses
between the blinking cycles. Visit our website for more details on the red
LED error codes.
Table 4: LED Behavior
Red LED Behavior
One (1) blink
Two (2) blinks
Three (3) blinks
Four (4) blinks
Five (5) blinks
Explanation
The lamp won't strike after five (5)
attempts. Check the lamp and lamp door
installations for loose connections.
The lamp counter hours have exceeded
lamp life hours. Replace the lamp and
reset the lamp hours counter.
The projector has shut down. Check to
see if the lamp door is open. If the lamp
door is closed, toggle off the projector
and wait one minute, then toggle the pro-
jector on again. If the lamp does not strike
after one minute, replace the lamp. Con-
tact Technical Support for repair if replac-
ing the lamp does not solve the problem.
The fan has failed. Contact Technical Sup-
port for repair or replacing the fan.
The projector is overheating. Check for a
blocked air vent (page 16). Contact Tech-
nical Support for repair if clearing the
vents/screens does not solve the problem.