WMF bistro! Service manual
131 F131 Current malfunction
hot water valve: current
consumption too high when
valve is addressed.
132 F132 Current malfunction
CW mixing-valve hot
water: current consumption
too high when valve is
addressed.
133 F133 Current malfunction
Brewing valve: current
consumption too high when
valve is addressed
134 F134 Current malfunction
cold water valve: current
consumption too high when
valve is addressed
137 F137 Current malfunction
choc mixer valve: current
consumption too high when
valve is addressed
138 F138 Current malfunction
steam boiler mixer valve:
current consumption
too high when valve is
addressed
140 F140 Current malfunction
steam dispensing valve 1:
current consumption
too high when valve is
addressed
141 F141 Current malfunction
steam dispensing valve 2:
current consumption
too high when valve is
addressed
142 F142 Current malfunction
cappucino valve 1: current
consumption too high when
valve is addressed
143 F143 Current malfunction
cappucino valve 21: current
consumption too high when
valve is addressed
30
√ Solenoid or wire
defect/short circuit
√ Solenoid or wire
defect/short circuit
√ Solenoid or wire
defect/short circuit
√ Solenoid or wire
defect/short circuit
√ Solenoid or wire
defect/short circuit
√ Solenoid or wire
defect/short circuit
√ Solenoid or wire
defect/short circuit
√ Solenoid or wire
defect/short circuit
√ Solenoid or wire
defect/short circuit
√ Solenoid or wire
defect/short circuit
Service manual WMF bistro! Edition 08/2011