Setting the SCSI ID on the Internal Scanner
The SCSI ID is set by a set of DIP switches on the back of the
internal-mount scanner as shown below. In most cases, these
DIP switches will not be changed.
Factory default for
COOLSCAN II
- 35 -
If it is necessary to change the default SCSI ID, change the
position of the DIP switches to the proper SCSI ID. Refer to
Table 5.2 for the proper DIP switch values. When changing the
position of the switches, use a pointed instrument to toggle the
switch. Use of a pen or pencil is not recommended, since these
will leave a mark on the switch and make it difficult to
differentiate between the "on" and "off" positions.
SCSI ID
DIP #1
0
Open
1
Closed
2
Open
3
Closed
4
Open
5
Closed
6
Open
7
Closed
Table 5.2 SCSI ID DIP switch values
DIP #2
DIP #3
Open
Open
Open
Open
Closed
Open
Closed
Open
Open
Closed
Open
Closed
Closed
Closed
Closed
Closed