Design and sizing information for connection on the flue gas side
– For plain tile, slate and other roof
covers. Colour: black or terracotta
Max. total length of the flue pipe
2
Vitodens 200-W, 222-F, 222-W and 242-F
Rated heating output range
Max. length - system size 60
Max. length - system size 80
Vitodens 200-W, from 45 kW
Rated heating output range
Max. length - system size 80
Max. length - system size 100
Vitodens 300-W, 333-F and 343-F
Rated heating output range
Max. length - system size 60
Max. length - system size 80
2 x 87º balanced flue bends are taken into consideration for the max-
imum flue lengths.

2.7 Plastic (PPs) balanced flue system for routing through a lightweight shaft

A space saving shaft for reduced temperature requirements may be
retrofitted if no shaft is available and the Vitodens is installed in the
living space with one or more full storeys above.

"UNIFIX" shaft profiles offered by Skoberne (made from aerated concrete)

a

"SKOBIFIXnano" and "SKOBIFIXXs 30" shaft profiles offered by Skoberne (made from foamed ceramics)

Fire rating 30 min.
Alternative system size. Balanced flue adaptor must be ordered separately.
*1
VIESMANN
24
System size Ø mm
60
80
100
kW
m
m
kW
17.0–45
17.0–60
m
12
m
*1
17
kW
m
m
Subtract additional bends, tees and straight lengths from the maximum
length using the following values:
■ Balanced flue bend 45º: 0.5 m
■ Balanced flue bend 87º: 1 m
■ Balanced flue inspection tee: 1.5 m
The shaft used must comply with the requirements for domestic chim-
neys to DIN V 18160-1 or must be generally approved by the building
inspectorate [Germany].
Ø mm
165
210
240
280
(cont.)
Pipe outlet for Klöber roof tiles
Colour: black or terracotta (provide
the corresponding Klöber roof tile on
site to match the roof outlet selected
for the particular type of roof cover)
Balanced flue adaptor
– Ø 80/125 mm to Ø 60/100 mm
– Ø 60/100 mm to Ø 80/125 mm
– Ø 80/125 mm to Ø 100/150 mm
3.2–13
3.2–19
20
20
*1
*1
25
25
30.0–80
30.0–100
12
*1
20
20
17
1.9–11
1.9–19
12
12
*1
*1
15
15
a
b
mm
mm
240
300
360
400
VITODENS AND VITOSOLAR
System size Ø mm
60
80
60
80
60
80
80
100
5.2–26
5.2–35
20
15
*1
*1
25
20
32–125
32–150
18
15
4.0–26
4.0–35
12
10
*1
*1
15
12
Fire rating
500
90 min
500
90 min
249
90 min
249
90 min

Advertisement