Putting the receiver into operation
CAUTION!
Rack mounting
one receiver
10
Mounting the receiver into a 19" rack
Do not mount the stacking elements and do not fit the rubber feet when rack moun-
ting the receiver.
Risks when rack mounting the receiver!
When installing the device in a closed or multi-rack assembly, please consider that, during
operation, the ambient temperature, the mechanical loading and the electrical potentials will
be different from those of devices which are not mounted into a rack.
Make sure that the ambient temperature within the rack does not exceed the permissible
temperature limit specified in the EM 100 G3 specifications.
Ensure sufficient ventilation; if necessary, provide additional ventilation.
Make sure that the mechanical loading of the rack is even.
When connecting to the power supply, observe the information indicated on the type
plate. Avoid circuit overloading. If necessary, provide overcurrent protection.
When rack mounting, please note that intrinsically harmless leakage currents of the
individual mains units may accumulate, thereby exceeding the allowable limit value.
As a remedy, ground the rack via an additional ground connection.
To mount the receiver into a rack, you require the GA 3 rack adapter (optional accessory):
Secure the rack mount "ears"
the same way as described for the stacking elements (see page 8).
Secure the blanking plate
screws (M 6x10) (see left-hand diagram).
Connect the antennas. There are two ways to connect the antennas:
– You can connect the rod antennas
case, insert the two blanking plugs
hand diagram).
– You can use the AM 2 antenna front mount kit (optional accessory) and mount the rod
antennas to the front of the receiver (see right-hand diagram).
When using more than one receiver, we recommend connecting remote antennas
and, if necessary, using Sennheiser antenna accessories. For more information, visit
the ew G3 product page at www.sennheiser.com.
Slide the receiver with the mounted blanking plate
Secure the rack mount "ears"
(supplied with the GA 3 rack adapter) to the receiver in
to one of the rack mount "ears"
to the rear of the receiver (see page 9). In this
into the holes of the blanking plate (see left-
into the 19" rack.
and the blanking plate
using two recessed head
to the 19" rack.

Advertisement