Fig. 5: NL4 cable connection with cover plate [1]
d&b 10A/10A-D Manual 1.2 en
NL4 connection with cover plate
The two NL4 connector sockets of the cabinet's connector panel
are located in a recess to allow the use of the cover plate [1]
together with NL4 cable connectors, as shown in the graphic
opposite.
Note: Neutrik NL4FC type connectors must be used for this
option.
The cover plate is equipped with two knockout openings to allow
daisy chaining of the loudspeaker.
To use the NL4 connection, proceed in the same manner as
described above in the section entitled Þ "Fixed cable
connection" on page 6.

2.3. Operation

NOTICE!
Only operate d&b loudspeakers with a correctly configured d&b
amplifier, otherwise there is a risk of damaging the loudspeaker
components.
Applicable d&b amplifiers:
10D/30D/D6/D12/D20/D80.
Application
Setup
10A
10S/A
10A-D
10S/A-D
Within applicable d&b amplifiers, the controller setups are
available in Dual Channel or Mix TOP/SUB mode.

2.3.1. Controller settings

For acoustic adjustment the functions CUT, HFA and CPL can be
selected.
CUT circuit
Set to CUT, the cabinet low frequency level is reduced. The
cabinets are now configured for use with d&b active subwoofers.
Cabinets per
channel
3
3
7