D&B xA 10A Manual page 10

Table of Contents

Advertisement

Fig. 12: Isobar diagram horizontal
Fig. 14: Isobar diagram horizontal
Fig. 16: Altering the HF dispersion
10
10A-D
vertical setup
Fig. 13: Isobar diagram vertical
10A-D
horizontal setup, horn
rotated
Fig. 15: Isobar diagram vertical
Altering the HF horn dispersion
The HF horn can be rotated through 90°.
Tools required: Philips screwdriver, Torx wrench (T20).
1. Undo the 4 torx screws on the top and bottom panels of the
cabinet and remove the front grill.
2. Undo the screws holding the horn flange and rotate the horn.
3. Refit the horn as follows:
– Make sure the gasket of the horn is in place.
– Refit the horn.
– Insert all screws and carefully tighten them clockwise until
they fit precisely into the counter sunk holes..
4. Relocate the front grill as follows:
– Ensure the foam is properly attached to the back of the grill.
– Starting on one side, attach the grill to the recess of the
cabinet's side panel.
– Fold down the grill into the recess on the other side and
make sure it properly fits on all sides.
– Insert the 4 torx screws and tighten them until they fit
precisely into the counter sunk holes.
d&b 10A/10A-D Manual 1.2 en