Greenstar regular boiler range
horizontal fluing options
The Greenstar regular boiler range have the choice of
2 differently sized horizontal RSF flue systems, a 100mm
diameter telescopic flue kit including a plume management
kit and a 125mm diameter telescopic flue kit. Both systems
have different maximum lengths. Options 1 to 6 detail the
permissible lengths.
Horizontal RS flue
Flue diameter
Greenstar Ri series
Minimum flue length
Maximum flue length
Greenstar CDi Classic Regular series
Minimum flue length
Maximum flue length
30CDi Classic Regular
40CDi Classic Regular
*Can be cut to 130mm. Please refer to instructions.
100mm dia. standard telescopic flue kit
Comprises:
1 x flue turret elbow
570mm (100mm dia.) of flue duct
1 x weather sealing ring
1 x internal collar
Part No. 7 716 191 082
125mm dia. standard telescopic flue kit
1 x flue turret elbow
600mm (125mm dia.) of flue duct including terminal
(as measured from centre of flue outlet)
1 x weather sealing plate
1 x internal plate
Part No. 7 719 003 702
Note: The maximum flue length must be reduced by the
following amounts for each bend used.
Greenstar Ri
– all size flues
45º bend
1m
90º bend
2m
26
100mm
125mm
350mm*
405mm
4,600mm
13,000mm
350mm*
405mm
7,900mm
18,500mm
6,000mm
12,500mm
Greenstar CDi
Greenstar CDi
Classic Regular
Classic Regular
60/100mm flues
80/125mm flues
0.75m
1m
1.5m
2m
Accessories
Components
Part no.
7 716 191 082
7 716 191 171
7 716 191 083
7 716 191 172 100mm dia. 2m flue extension
7 716 191 133
7 716 191 084 100mm dia. 90º bend
7 716 191 085 100mm dia. 45º bend
7 719 002 432
7 716 191 092 100mm dia. support bracket kit
7 716 191 173
7 719 003 702
7 719 003 666
7 719 003 664 125mm dia. 90º bend
7 719 003 665 125mm dia. 45º bend
7 719 002 433
7 716 191 174 125mm dia. support bracket kit
*Dimensions when fitted
The following criteria should be noted when planning
the installation.
The concentric flue system must be inclined at 3º
(50mm per metre) from the appliance, to allow
condensate to drain back into the boiler.
Because the appliance operates at high efficiency a
white plume of condensation will be emitted from the
terminal. Care must be taken when selecting the flue
terminal position.
Description
100mm dia. standard telescopic
flue kit (350 - 570mm)
100mm dia. long telescopic
flue kit (570 - 790mm)
100mm dia. extension flue kit
(960mm*)
100mm dia. short flue extension
(220mm*)
100mm dia. high level
horizontal adaptor
100mm dia. support bracket kit
(6 pack)
125mm dia. standard telescopic
flue kit
125mm dia. extension flue kit
(960mm*)
125mm dia. high level
horizontal adaptor