Friedrich ZStar ZQ05A10B Service And Parts Manual page 18

Hide thumbs Also See for ZStar ZQ05A10B:
Table of Contents

Advertisement

Check of power source.
Check of control switch
setting.
Compressor fails only to
start.
Drop of power voltage.
Defect of compressor
capacitor.
Capacitor check.
Replacement.
Irregular motor resistance (Ω)
Irregular motor insulation (Ω)
Replacement of compressor
(Motor damaged).
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Fails to Start
Improper thermostat
setting
Loose terminal
connection
Improper wiring
- 18 -
Check of circuit breaker
and fuse.
Gas leakage of feeler
bulb of thermostat.
Check control switch.
Fan only fails to start.
Improper wiring.
Defect of fan motor
capacitor.
Irregular motor
resistance (Ω)
Irregular motor
insulation (Ω)
Replacement of fan motor.
Regular but fails to start.
Replacement of compressor.
(Locking of piston, metal.)
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zstar zq07a10b