Figure 48 Pc Data (Rs232) Connection - Raymarine AIS950 Installation Instructions Manual

Table of Contents

Advertisement

The alarm relay is rated to 220VDC or 2ADC or 60W maximum. The alarm connections provided at the power
connections are a duplicate of the those available via the junction box and described in section 4.4.
A chassis ground stud is provided on the rear panel of the transceiver. Note that the transceiver chassis is
isolated from the incoming power supply so this stud must not be connected to power supply ground.
4.4.6
PC data connection
A 9 way D-type connector is provided on the rear panel of the AIS950 transceiver. This interface allows direct
connection to a PC RS232 interface and can be used for installation, diagnostics or external display
connection. The default configuration for this interface allows connection of an ECDIS or charting system and
duplicates the 'External display' port in the junction box.

Figure 48 PC data (RS232) connection

The RS232 port is galvanically isolated from the incoming power supply.
The pin allocation for the 9 way D-type socket on the rear panel of the transceiver is shown in Table 7.
Transceiver 9 Way
D-type pin
1
2
3
4
5
6
7
8
9
Table 7
Pin allocation for the 9 way D-type socket
PC data (RS232) connection
Signal
No connection
RS232 Transmit
RS232 Receive
No connection
RS232 Ground
No connection
No connection
No connection
No connection
Function
Connect to PC RS232 receive
Connect to PC RS232 transmit
Connect to PC RS232 ground
Installation
Page 45