Noritz NR111-SV Installation Manual
Hide thumbs Also See for NR111-SV:

Advertisement

Quick Links

Installation Manual

TANKLESS GAS WATER HEATER
Potential dangers from accidents during installation and use are divided into the following three
categories. Closely observe these warnings, they are critical to your safety.
DANGER
WARNING
CAUTION
WARNING:
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
Prohibited
Requests to Installers
• In order to use the water heater safely, read this installation manual carefully, and follow the
installation instructions.
• Failures and damage caused by erroneous work or work not as instructed in this manual are not
covered by the warranty.
• Check that the installation was done properly in accordance with this Installation Manual upon
completion.
• After completing installation, please either place this Installation Manual in a plastic pouch and
attach it to the side of the water heater (or the inside of the pipe cover or recess box if applicable),
or hand it to the customer to retain for future reference. Also, be sure to fill in all of the required
items on the warranty and to hand the warranty to the customer along with the Owner's Guide.
CERTIFIED
R
Complies with
jurisdictions having
40 ng/J or 55 ppm
NOx regulations
(Natural Gas Only)
SBA8374-2
Rev. 03/13
NR111-SV
(Indoor/Outdoor Installation)
DANGER indicates an imminently hazardous situation which,
if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
if not avoided, may result in minor or moderate injury.
Disconnect
Power
CAUTION
Ground
Installation must conform with local codes, or in the
absence of local codes, the National Fuel Gas Code,
ANSI Z223.1/NFPA 54- latest edition and/or CSA
B149.1, Natural Gas and Propane Installation Code
(NSCNGPIC).
Noritz America reserves the right to discontinue, or
change at any time, the designs and/or specifications
of its products without notice.
NORITZ AMERICA
CORPORATION
Be sure to do
*SBA8374*

Advertisement

Table of Contents
loading

Summary of Contents for Noritz NR111-SV

  • Page 1: Installation Manual

    B149.1, Natural Gas and Propane Installation Code (NSCNGPIC). Complies with jurisdictions having Noritz America reserves the right to discontinue, or change at any time, the designs and/or specifications 40 ng/J or 55 ppm of its products without notice. NOx regulations...
  • Page 2: Included Accessories

    The following accessories are included with the unit. Included Accessories Check for any missing items before starting installation. Part Shape Part Shape Q’ty Q’ty Owner's Guide, Warranty, Anchoring Screw Installation Manual each (this document) Remote Controller Remote Controller (See p. 20) Cord (10ft) Power Cord The accessories listed below are not...
  • Page 3: Quick Connect Multi System Installation

    Quick Connect Multi System Installation • The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord. The Quick Connect Cord is 6 ft. long. Install the units 2-19" apart from each other to ensure the cord will be able to reach between the units.
  • Page 4: Before Installation

    Before Installation DANGER Checkup • Check the fixing brackets and vent pipe yearly for damage or wear. Replace if necessary. WARNING Check the Gas • Check that the rating plate indicates the correct type of gas. • Check that the gas supply line is sized for 250,000 Btuh for this unit.
  • Page 5: Choosing Installation Site

    Choosing Installation Site * Locate the appliance in an area where leakage from the unit or connections will not result in damage to the area adjacent to the appliance or to the lower floors of the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the appliance.
  • Page 6 Contact local utilities for code requirements in your area or call: 1-866-766-7489 and request instructions. The Commonwealth of Massachusetts: The water heater can be used for hot water only and not in a combination of domestic and space heating. For Venting Manufacturers Requirements, see websites or phone numbers listed below: Noritz N-Vent www.noritz.com...
  • Page 7: Installation Clearances

    Installation Clearances WARNING Before installing, check for the following: Install in accordance with relevant building and mechanical codes, as well as any local, state or national regulations, or in the absence of local and state codes, to the National Fuel Gas Code ANSI Z223.1/NFPA 54 –...
  • Page 8 Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. Vent Terminal Area Where Terminal is Not Permitted Air Supply Inlet Canadian Non-Direct Vent US Non-Direct Vent...
  • Page 9: Installation

    Installation Securing to the wall • The weight of the device will be applied to the wall. If the strength of the wall is not suffi- cient, reinforcement must be done to prevent the transfer of vibration. • Do not drop or apply unnecessary force to the device when installing. Internal parts may be damaged and may become highly dangerous.
  • Page 10: Vent Pipe Installation

    • The first vertical run from the top of the heater Vent Piping should be no longer than 3'. • Noritz N-Vent is suggested for the vent system. • Make sure vent pipe is gas tight and will not If N-Vent is not used, a UL listed category III vent leak.
  • Page 11: Vertical Vent Termination

    National Adapter* Fuel Gas Code ANSI Z223.1/NFPA 54. * Adapter not required when using Noritz N-Vent. • Slope the horizontal vent 1/4" downwards for every 12" toward the termination. **1' minimum recommended, but not required. Avoid installing •...
  • Page 12: Combustion Air

    Supply combustion air to the units as per the National Fuel Gas Code, ANSI Z223.1 and Combustion Air in Canada, in accordance with NSCNGPIC. • Provide two permanent openings to allow circulation of combustion air. 15" • Make each opening 250 square inches if they 20"...
  • Page 13: Gas Piping

    Instructions Sample Gas Line 1. Size each outlet branch starting from the furthest Noritz Tankless Gas Water Heater using the Btuh required and the length from the Barbecue (250,000 Btuh) (50,000 Btuh) meter.
  • Page 14 Gas Line Sizing for a Noritz Tankless Gas Water Heater Adapted from UPC 1997 Maximum Natur Natural Gas Delivery Capacity in Cubic Feet per Hour (0.60 Specific Gravity, 0.5" WC Pressure Drop) Length in Feet Pipe Size 100' 125' 1/2"...
  • Page 15: Water Piping

    Installation and service must be performed by a qualified plumber. In the Water Piping Commonwealth of Massachusetts, this product must be installed by a licensed plumber or gas fitter in accordance with the Massachusetts Plumbing and Fuel Gas Code 248 CMR Sections 2.00 and 5.00. Observe all applicable codes. This appliance is suitable for potable water and space heating applications.
  • Page 16: Drain Piping

    Supply water piping Hot water piping • Do not use PVC, iron, or any piping which has been • Do not use lead, PVC, iron or any piping which treated with chromates, boiler seal or other chemicals. has been treated with chromates, boiler seal or •...
  • Page 17: Water Treatment

    If this water heater will be installed in an application where the supply water is hard, the water must be treated with either the Noritz H2Flow or ScaleShield or a water softener. Refer to the below tables for suggested treatment and maintenance measures to be taken based on the water hardness level.
  • Page 18: Plumbing Applications

    (Model L6006A or L6006C) Combination Potable Water and Space Heating System Notes: 1. Noritz recommends the use of an Isolation Kit with the installation. These kits include an integrated shut-off and serv- ice valve with unions and a pressure relief valve.
  • Page 19: Electrical Wiring

    Consult a qualified electrician Electrical Wiring for the electrical work. Do not connect electrical power to the unit until all electrical wiring has been completed. Disconnect Power This appliance must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
  • Page 20: Remote Controller

    To keep the water heater off, let the unit sit for 30 sec. to return to the original display. • The NR111-SV can be programmed so that it will default to one of four temperatures if the remote control- ler is removed (180, 140, 130, 120°F). To change the default temperature, connect the temperature selection wire as shown in the above diagram.
  • Page 21 Connecting Remote Controller Cord to Unit • Keep the remote controller cord away from the freeze prevention heaters in the unit. • Tie the redundant cord outside the water heater. Do not put the extra length inside the equipment. • The remote controller cord can be extended up to 300' with 18AWG wire. •...
  • Page 22: Pump Wiring

    * This feature is not available when using the Quick Con- Pump Wiring nect Multi System feature. Connecting the pump control wire 1. Leave enough slack so that the pump control wires will stay connected if the unit is removed Pump Control from the wall.
  • Page 23 For Quick Connect Multi System Installation Connecting Quick Connect Cord use a Quick Connect Cord (sold separately). Caution The wire coloring on the Quick Connect Cord will not be the same as the wire coloring of the connection plug inside the unit. 1.Red 1.Red 1.White...
  • Page 24: Maintenance

    Periodically check the following to ensure proper Maintenance operation of the water heater. • The venting system must be examined periodically by a qualified service technician to check for any leaks or corrosion. • The burner flame must be checked periodically for a proper blue color and consistency. •...
  • Page 25: Lighting Instructions

    CAUTION Handling after trial operation • If the unit will not be used immediately, close off all gas and water shutoff valves, drain all of the water out of the unit and the plumbing system to prevent the unit and system from freezing, and bleed the gas out of the gas line.
  • Page 26 Dimensions NR111-SV 17.7" < inch > 4- 0.5" 6-0.24 x 0.4" OBLONG HOLE 18.3" 6.7" 5.5" 17.6" 0.4" 9.4" 3.9" 4" FLUE COLLAR 2.8" 3.7" 1.4" 1.1" AIR INLET AIR INLET 0.4" 1.4" WIRING THROUGHWAYS GAS INLET 2.8" 3.9" 5.5"...
  • Page 27 Remote Controller RC-7649M carefully before carrying out installation. Installation Guide NORITZ AMERICA CORPORATION Note Do not connect power to the water heater before the remote controller has been properly installed. Recommended installation location of the remote controller is in a bathroom.
  • Page 28 Installation 3. Remove the cover of the remote control, 1. Apply Wall Packing to the rear side of the mark the location of the screw holes, and remote controller. drill holes for the wall anchors. 2. Connect the remote controller wires to the 4.
  • Page 29 Installing the Remote Controller Outdoor Junction Box 5. Slide the box nut over the remote controller 1. Insert the remote controller wires through the wires and screw it onto the wall pipe. wall pipe and secure the wall pipe to the remote controller.

Table of Contents