Premises Wiring - Red-D-Arc ZR-8 Operator's Manual

Hide thumbs Also See for ZR-8:
Table of Contents

Advertisement

A-9
POWER
240 Volt
60 Hz.
COMPANY
3-Wire
Service
METER
DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.
50 AMP, 120/240
VOLT PLUG
NEMA TYPE 14-50
50 AMP, 120/240 VOLT
RECEPTACLE
INSTALLATION
Figure 1
CONNECTION OF ZR-8 TO PREMISES WIRING
240 VOLT
120 VOLT
120 VOLT
240 VOLT
WARNING
Connection of ZR-8 to premises wiring must be
done by a licensed electrician and must comply
with the National Electrical Code and all other
applicable electrical codes.
GROUNDED CONDUCTOR
40 AMP
240 VOLT
DOUBLE
POLE
CIRCUIT
BREAKER
GND
N
NOTE: No. 6 COPPER CONDUCTOR CABLE SEE
NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE
ZR-8
NEUTRAL
BUS
N
PREMISES
DISCONNECT AND
SERVICE
GROUND
OVERCURRENT
PROTECTION
SIZE RECOMMENDATIONS.
A-9
LOAD