Connection Of Zr-10 To Premises Wiring - Red-D-Arc ZR-10 Operation Manual

Table of Contents

Advertisement

B-8
POWER
230 Volt
60 Hz.
COMPANY
3-Wire
Service
METER
DOUBLE POLE DOUBLE THROW
SWITCH RATING TO BE THE SAME
AS OR GREATER THAN PREMISES
SERVICE OVERCURRENT
PROTECTION.
50 AMP, 115/230
VOLT PLUG
NEMA TYPE 14-50
50 AMP, 115/230 VOLT
RECEPTACLE
OPERATION
Figure 1

CONNECTION OF ZR-10 TO PREMISES WIRING

230 VOLT
115 VOLT
115 VOLT
230 VOLT
Connection of ZR-10 to premises wiring must be
done by a licensed electrician and must comply
with the National Electrical Code and all other
applicable electrical codes.
GROUNDED CONDUCTOR
35AMP
230 VOLT
DOUBLE
POLE
CIRCUIT
BREAKER
GND
N
NOTE: No. 8 COPPER CONDUCTOR CABLE SEE
NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE
WARNING
ZR-10
NEUTRAL
BUS
N
PREMISES
DISCONNECT AND
SERVICE
GROUND
OVERCURRENT
PROTECTION
SIZE RECOMMENDATIONS.
B-8
LOAD