This product has a switchable power supply that can work with an input voltage
of 120 VAC, 60 Hz or 230 VAC, 50 Hz.
For the maximum number of LFS-75DMX products that you can power link
at each voltage, refer to the sticker on the product or the User Manual.
1.
Disconnect the product from power.
2.
Using a flat-head screwdriver, loosen the fuse holder and pull straight
out.
3.
Remove the blown fuse from the holder and replace with a fuse of the
exact same type and rating.
4.
Re-insert the fuse holder and reconnect power.