8.2
Setting pressure reducer
Setting pressure reducer without laptop
Start service program
pressure reducer
Remove screw-cap on descaling nozzle.
Screw auxiliary nipple to accept plug-in connector into
the descaling nozzle.
Mount auxiliary tool on descaling nozzle.
Press field
Start
Supply valve opens
Read pressure on pressure gauge.
Set pressure to 1.8 bar at pressure reducer.
Finish test.
Dismantle setting equipment and remove auxiliary
nipple.
Replace filler cap.
Setting pressure reducer with KonfigTool
Adjust test environment
Remove screw-cap on descaling nozzle.
Screw auxiliary nipple to accept plug-in connector into
the descaling nozzle.
Mount auxiliary tool on descaling nozzle.
Start test on laptop
Supply valve opens
Read pressure on pressure gauge.
Set pressure to 1.8 bar at pressure reducer.
Finish test
Dismantle setting equipment and remove auxiliary
nipple.
Replace filler cap.
WMF 2000S Service Manual edition 06/2012
service routine
start.
set pressure reducer
WMF 2000S Service Manual
setting
start