8.2

Setting pressure reducer

Setting pressure reducer without laptop
™ Start service program
pressure reducer
 
™ Remove screw-cap on descaling nozzle.
™ Screw auxiliary nipple to accept plug-in connector into
the descaling nozzle.
™ Mount auxiliary tool on descaling nozzle.
™ Press field
Start
Supply valve opens
™ Read pressure on pressure gauge.
™ Set pressure to 1.8 bar at pressure reducer.
™ Finish test.
™ Dismantle setting equipment and remove auxiliary
nipple.
™ Replace filler cap.
Setting pressure reducer with KonfigTool
™ Adjust test environment
™ Remove screw-cap on descaling nozzle.
™ Screw auxiliary nipple to accept plug-in connector into
the descaling nozzle.
™ Mount auxiliary tool on descaling nozzle.
™ Start test on laptop
Supply valve opens
™ Read pressure on pressure gauge.
™ Set pressure to 1.8 bar at pressure reducer.
™ Finish test
™ Dismantle setting equipment and remove auxiliary
nipple.
™ Replace filler cap.
WMF 2000S Service Manual edition 06/2012
service routine
 
start.
set pressure reducer
 