Installer Setup; Installer System Test; Setup Function; Settings & Options - Honeywell PRO TH3210D Manual

Non-programmable digital thermostat
Hide thumbs Also See for PRO TH3210D:
Table of Contents

Advertisement

PRO TH3210D Non-programmable
Digital Thermostat
Follow the procedure
below to configure
the thermostat
to match the installed
heating/cooling
system, and customize feature operation
as desired.
Prose
and hold both buttons
Function
Setting
number
To begin, press and hold the A and Y
buttons until the display changes
Press V to change settings
Press A to advance
to next function
Press and hold T_,
to exit and save settings
Setup Function
6 Auxiliary
heat
cycle rate (CPH)
8 Emergency
heat
cycle rate (CPH)
9 Compressor
cycle rate (CPH)
Settings & Options
5
For gas or oil furnaces
of less than 90% efficiency
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
9
For electric furnaces
[Other cycle rate options:
2, 4, 6, 7, 8, 10, 11 or 12 CPH]
9
For electric
furnaces
1
For steam or gravity systems
3
For hot water systems & furnaces of over 90% efficiency
5
For gas or oil furnaces
of less than 90% efficiency
[Other cycle rate options:
2, 4, 6, 7, 8, 10, 11 or 12 CPH]
Recommended
for most compressors
[Other cycle rate options:
1, 2, 4, 5 or 6 CPH]
14 Temperature
0
Fahrenheit
display
1
Celsius
15 Compressor
protection
5
Five-minute
compressor
off time **See page 9
[Other options:
0, 1, 2, 3 or 4-minute
off time]
After completing
the installer setup above, press the & button again to begin a
system test (see next page).

Hide quick links:

Advertisement

Table of Contents
loading