About The Appliance; Determined Use; Eu Declaration Of Conformity; Operating Conditions - Buderus Logano plus SB325 Operating Instructions For User

Floor standing condensing boiler
Hide thumbs Also See for Logano plus SB325:
Table of Contents

Advertisement

2

About the appliance

Inspection and service
▶ Recommendation for customers: Arrange a service and inspection
contract with the service department of the manufacturer or with an
authorised contractor, covering an annual inspection and demand-
dependent service.
▶ The user is responsible for the general and environmental safety of
the heating system.
▶ Immediately correct all faults to prevent system damage!
▶ Use only genuine spare parts from the manufacturer. Losses caused
by the use of spare parts and accessories not supplied by the
manufacturer are excluded from the manufacturer's warranty.
Explosive and highly flammable material
▶ Never use or store highly flammable materials (paper, thinners, paints
etc.) near the boiler.
Combustion/room air
▶ Keep the combustion/ambient air free of corrosive substances
(e.g. halogenated hydrocarbons that contain chlorine or fluorine
compounds). This will help prevent corrosion.
▶ Keep the combustion air supply free of dust.
Disposal
▶ Dispose of packaging in an environmentally responsible manner.
4
2
About the appliance
2.1

Determined use

The Logano plus SB325 condensing boiler has been designed for hot
water heating systems in e.g. apartment buildings or industrial units.
The boiler is only approved for open flue operation.
Any pressure-jet gas burner type-tested to EN 676 can be used if its
operating range matches the boiler specifications.
Only burners that have been tested and approved for electromagnetic
compatibility (EMC) may be used.
2.2

EU Declaration of Conformity

The design and operation of this product conform to the applicable
European directives and supplementary national requirements.
Conformity has been demonstrated.
You can ask for a copy of the declaration of conformity for this product.
For this see the contact address on the back of these instructions.
2.3

Operating conditions

Observe all standards and directives applicable to the
installation and operation of this heating system in your
country. Observe the information on the data plate.
These are definitive and must be observed.
Set the burner to the rated heat input QN specified on
the data plate as a maximum.
Conditions of use
Maximum permissible temperature,
high-limit safety cut-out
Maximum operating pressure
Maximum number of burner starts
Table 2 Conditions of use
Operating conditions
Logano plus SB325
Boiler water flow rate
None –
in conjunction with a
Min. boiler water
Logamatic control unit
temperature
for modulating
Operating Interruption
operation.
(complete boiler shut-down)
Heating system control
with mixer
Minimum return
temperature
Miscellaneous
Table 3 Operating conditions
1) Maximum 15,000 burner starts per year. In order not to exceed the number of
burner starts, observe the information on setting the control unit and burner in the
technical guide or installation instructions. If this value is exceeded, however,
please contact the manufacturer's service department.
2) The number of burner starts per year is affected by the boiler system's operating
settings (controller parameters in the boiler controller and combustion setting)
and sizing to correspond with the consumers' heat demand. To avoid exceeding
the number of annual burner starts as a result of operating settings which have not
been optimised, the manufacturer offers a complete commissioning and regular
document inspections for floor standing residential conventional boilers, burners
and boiler controller (Logamatic control units with function modules).
Logano plus SB325 – 6 720 806 353 (2012/07)
Unit
Value
°C
110
bar
4
per annum 15 000
Logano plus SB325
None –
in conjunction with a
Logamatic control unit
4212 for constant
boiler water
temperatures or when
supplemented by a
third party control
unit.
1)2)
1)