4. Focus Assistance Drive Adjustment
Camera
Adjustment location: Focus of computer screen
Measuring location: Computer screen
Measuring equipment:
Subject: Note:
Do not vibrate during the adjustment.
Lens is set on TELE edge.
If using a ready-made collimator, set to infinity.
Adjustment method:
1. Connect the camera's USB terminal to the computer'
USB connector.
2. It turns on power while pushing the FAR button and the
SET button of the operation panel.
3. Double-click on the DscCalDi.exe.
4. Click the "Focus", and Click the "Yes".
5. Lens adjustment value will appear on the screen.
6. Click the OK.
Adjustment value determination is effectuated using below val-
ues.
The adjustment values fulfill the conditions below, they are
determined as within specifications.
Adjustment value determination
AF_I_WIDE = 0 ± 2500, AF_I_MID1 = Reference value,
AF_I_MID2 = 0, AF_I_MID3 = 0, AF_I_MID4 = 0,
AF_I_MID5 = 0, AF_I_MID6 = 0, AF_I_TELE = 0,
QR_Z_WIDE = 0, QR_F_I_WIDE = 0, QR_F_I_TELE = 0,
QR_Z_AORI = 0, QR_F_I_AORI = 0, IRIS_GAIN = 0,
IRIS_OFFSET = 0
Collimator
2-6. Overwriting firmware from the calibration
software
Preparation:
PC with overwriting firmware copied to the preferred folder in
the HD.
Data: s32xxxxx.BIN (xxxxx: version)
Overwriting method:
1. Connect the camera's USB terminal to the computer'
USB connector.
2. It turns on power while pushing the FAR button and the
SET button of the operation panel.
3. Double-click on the DscCalDi.exe.
4. Click the Firmware.
5. Choose the fimware file to use for overwriting, and click
the Yes.
6. Update is starting. The message will appear, and choose
OK.
7. After the update is complete, disconnect the USB cable
and turn the camera's power off.