Split system (3-phase)

4 Configuring the installation

" Optional DHW kit
DHW tank control (with electrical back-up) requires the
use of the DHW kit.
Warning ! The tank must be fitted with an electric
back-up, particularly for anti-legionella cycles.
Please refer to section "Operating principle",
" Optional 2nd circuit kit
The control of 2 heating circuits requires the installation
of the 2
circuit.
nd
If the installation consists of radiators (or fan-convectors)
and a heated floor, zone 2 will correspond to the radiator
(or fan-convectors) zone and zone 1 to the heated
floor zone.
Configuration
Type of installation
(Parameter 5700)
Pre-setting 1
1 heating circuit.
Pre-setting 2
1 heating circuit and DHW tank.
Pre-setting 3
2 heating circuits.
Pre-setting 4
2 heating circuits and DHW tank.
Pre-setting 5
Boiler connection and 1 heating circuit.
Pre-setting 6
Boiler connection and 2 heating circuits.
Pre-setting 7
Boiler connection, 1 heating circuit and DHW tank.
Pre-setting 8
Boiler connection, 2 heating circuits and DHW tank.
Pre-setting 9
Pre-setting 10
Do not use for heat pump single service Reserved only for heat pump 2 services
Pre-setting 11
Pre-setting 12
" Please consult us regarding any other installation configuration.
- 46 -
" Optional boiler connection kit
The connection of an oil or gas boiler to the heat pump
requires the installation of the boiler connection kit.
" Swimming pool kit option
page 11
Please refer to the instructions supplied with the
swimming pool kit.
Please refer to the
instructions supplied with
the boiler connection kit.