Technical Data; Installing The Greenstar Heatslave Series - Worcester Greenstar Heatslave 12/18 Technical Information

Hide thumbs Also See for Greenstar Heatslave 12/18:
Table of Contents

Advertisement

Technical data – Greenstar Heatslave series
Model
Greenstar Heatslave
Primary water capacity (total) (litres)
Maximum static head (metres)
Minimum static head (metres)
Exit flue gas mass flow (kg/hr)
Conventional flue (min. dia. required)
(mm)
(kitchen models)
Room sealed flue (dia.) (mm)
Fuel line (compression) (mm)
CH flow (mm)
Mains water inlet (mm)
DHW outlet (mm)
CH return (mm)
CH vent (optional)
CH make-up (cold feed)
Condensate (polypropylene) (mm)
Electrical power supply voltage (AC V)
Frequency (Hz)
Maximum power consumption (W)
CH flow temperature range
(min/max) (ºC)
DHW t/stat range (ºC)
CH control thermostat differential (ºC)
Boiler high limit thermostat
(cut out) (ºC)
Boiler manual reset overheat
thermostat (cut out) (ºC)
Flue reset overheat thermostat
(cut out) (ºC)
Maximum hearth temperature (ºC)
SEDBUK value %/band
Appliance protection rating
(with programmer blanking plate fitted)
(kitchen models)
Appliance protection rating
(with fascia programmer fitted)
(kitchen models)
Appliance protection rating
(external models)
Weight (kg)
(kitchen models)
Weight (kg)
(external models)
10
Greenstar Heatslave
Greenstar Heatslave
12/18
18/25
69
69
30
30
1
1
29
40
100
100
80/125
80/125
10
10
22
22
15
15
22
22
22
22
1" BSP
1" BSP
3/4" BSP
3/4" BSP
21.5
21.5
230
230
50
50
240
240
55/81
55/81
55/72
55/72
5
5
92
92
105
105
110
110
100
100
90.2%/Band A
90.1%/Band A
IP 20
IP 20
IP 20
IP 20
IP 45
IP 45
177
177
195
195

Installing the Greenstar Heatslave series

(kitchen models)
25/32
72
30
Installation
1
General
51
The Greenstar Heatslave oil-fired floor standing appliance is
not suitable for external installation unless a suitable
100
enclosure is provided. The floor must be firm and level.
80/125
10
The floor on which the boiler is to be mounted should be
capable of supporting an overall weight of approximately
28
251kg. The appliance has a hearth temperature of below
15
100°C. The boiler does not therefore require a
22
constructional hearth.
28
The appliance should however be positioned on a non-
1" BSP
permeable solid base. Care should be taken to ensure that
3/4" BSP
the appliance is level.
21.5
230
Flue system
50
The appliance can be connected to either an open flue
263
system or a multi directional, room sealed balanced flue.
In either case either the conventional flue adaptor or the
55/81
appropriate RS flue kit needs to be specified.
55/72
5
All materials used on open flue systems must be able to
withstand the corrosive elements present within the flue
92
gases from condensing boilers. Stainless steel of certain
grades is permissible and guidance should be sought from
105
the flue manufacturer. Contact RITE Vent,
Tel: 0191 416 1150, SFL, Tel: 01271 326633,
110
Interactive, Tel: 01908 569887.
100
Casing dimensions
90.3%/Band A
B
C
IP 20
IP 20
IP 45
179
206
Siting of appliance
Clearances
The following clearances should be allowed for installation
and servicing.
Recommended installation clearances
The minimum space required to install the boiler.
C
F
B
E
Service clearances
The minimum space required to service the boiler only.
Access will be required to condensate trap to the right of
the boiler.
C
F
B
E
Cabinet dimensions (mm)
A
855
B
520
C
600
A
Dimensions (mm)
A
D
A
720
B
100
C
1,200
D
300
E
600
F
1,155
B
Dimensions (mm)
A
D
A
530
B
5
C
1,200
D
300
E
600
F
1,155
B
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar heatslave 18/25Greenstar heatslave 25/32