Philips S37SD-YD02 Service Manual page 68

Hide thumbs Also See for S37SD-YD02:
Table of Contents

Advertisement

EN 68
8.
8.8
Alignments 50" HD v4
1. Get Pattern to be Full White(jumper CN2012 on Logic Brd).
2. Check the waveform using Oscilloscope.
Triggering through V_TOGG of LOGIC Board.
Connect the CN5511 Test Point at the Y_buffer to
other channel, and then check the first SF operating
waveform of 1TV-Field.
ComPair
Adjust VR5000 to set the time of
Yrr (Main Reset Rising Ramp)
SDI PDP
Alignments
CN2012
Figure 8-44 Jumper CN2012 / ComPair connector on v4 Logic board
1 st Sub Field
90 us
Figure 8-45 TCP ramp waveform inclination adjustment (Y-Board)
Check the waveform as before by adjusting Horizontal
Division. Check the Reset waveform when the
V_TOGG Level is changed.
Set the Rising Ramp Flat Time to 90 µs by adjusting
VR5000.
Set the Falling maintenance time to 80 µs by adjusting
VR5001.
Adjust VR5001 to set the time of
Yfr (Main Reset Falling Ramp) 80 us
F_14991_052.eps
081105
F_14991_020.eps
030805