Philips S37SD-YD02 Service Manual page 47

Hide thumbs Also See for S37SD-YD02:
Table of Contents

Advertisement

Block Diagrams, Test Point Overview, and Waveforms
6.2.4
PSU 42" SD v4
Table 6-4 Adjustment voltage level overview
No
Output voltage (V)
1
VS
2
VA
3
VE
4
VSET
5
VSCAN
6
VSB
7
VG
8
D5VL
9
D3V3
Check voltage label on the PDP for correct values.
Figure 6-12 PSU layout
Voltage Setting (Normal Load)
207V ± 1%
70V ± 1.5%
110V ± 1.5%
198V ± 1.5%
-185V ± 1.5%
5V ± 5%
15V ± 5%
5.2V ± 5%
3.3V ± 5%
SDI PDP
F_14991_061.eps
Output Voltage Variable Point
195V ~ 215V
50V ~ 70V
70V ~ 110V
180V ~ 210V
-170V ~ -190V
Fixed
Fixed
Fixed
Fixed
6.
EN 47
120206