7 CLEARANCES TO HEAT‐SENSITIVE MATERIALS 
It is of outmost importance that the clearances to heat‐sensitive materials be carefully maintained 
upon installation of the wood fire you have selected. Refer to the tables below.  
No  part  of  the  wood  fire  or  flue  may  be  located  closer  to  combustibles  than  the  minimum 
clearance figures given. 
7.1 LOCATION OF THE CERTIFICATION LABEL 
Since the information given on the certification label affixed to the appliance always overrides the 
information published, in any other media (owner's manual, catalogues, flyers, magazines and/or 
web  sites)  it  is  important  to  refer  to  it  in  order  to  have  a  safe  and  compliant  installation.  In 
addition, you will find information about your wood fire (model, serial number, etc.). You can find 
the certification label on the back of the wood fire. 
7.2 CLEARANCES TO WALLS AND CEILING 
WHERE  THE  FLUE  PASSES  THROUGH  A  WALL,  CEILING,  FLOOR  OR  ROOFS,  VENTILATED  DOUBLE 
FLUE‐WOOD FIRE CASINGS MUST BE USED AROUND THE FLUE, ALONG WITH CEILING PLATES AS 
SPECIFIED  IN  AS/NZS  2918:2001.  THE  CASING  SHALL  PASS  THROUGH  THE  ENTIRE  THICKNESS  OF 
WALL, CEILING OR WALL. 
 
See figure Clearances to heat sensitive materials and floor protection to match each letter to a 
clearance. 
 
 Top of appliance to ceiling height must be at least 1,500 mm in all cases. 
 The clearance between the flue and a wall are valid only for vertical walls and for vertical 
flue. 
 
 
 
OPERATING & INSTALLATION INSTRUCTIONS FOR PEDESTAL WOOD HEATERS
 
CLEARANCES 
(TRIPLE SKIN FLUE) 
150 mm 
350 mm  
100 mm  
 
25 