7 CLEARANCES TO HEAT-SENSITIVE MATERIALS

It is of outmost importance that the clearances to heat-sensitive materials are carefully
maintained upon the installation of the wood fire you have selected. Refer to the tables below.
No part of the wood fire or flue may be located closer to the combustible than the minimum
clearance figures given.

7.1 LOCATION OF THE CERTIFICATION LABEL

Since the information given on the certification label affixed to the appliance always overrides the
information published, in any other media (owner's manual, catalogues, flyers, magazines or web
sites) it is important to refer to it in order to have a safe and compliant installation. In addition,
you will find information about your wood fire (model, serial number, etc.). You can find the
certification label on the back of the wood fire.

7.2 CLEARANCES TO WALLS AND CEILING

WHERE THE FLUE PASSES THROUGH A WALL, CEILING, FLOOR OR ROOFS, VENTILATED DOUBLE
FLUE-WOOD FIRE CASINGS MUST BE USED AROUND THE FLUE, ALONG WITH CEILING PLATES AS
SPECIFIED IN AS/NZS 2918:2001. THE CASING SHALL PASS THROUGH THE ENTIRE THICKNESS OF
THE WALL, CEILING OR WALL.
See figure Clearances to heat sensitive materials and floor protection to match each letter to a
clearance.
• Top of appliance to ceiling height must be at least 1,200 mm in all cases.
• The clearance between the flue and a wall are valid only for vertical walls and for vertical flue.
Clearances to heat-sensitive materials and floor protection
24
CLEARANCES
(TRIPLE SKIN FLUE)
A
275 mm
B
775 mm
C
325 mm
OPERATING & INSTALLATION INSTRUCTIONS FOR ECOMAXX HT2000 WOOD HEATER