FILLING THE SOLUTION TANK

Fill the solution tank with a maximum of 21 gallons (79.5 Liters) for SC750/SC750 ST models and 25 gallons (94.6 Liters) for SC800/SC800 ST
models of cleaning solution. Do not fi ll the solution tank above 7.5 cm (3 inches) from the bottom of the Solution Fill (1). The solution should be
a mixture of water and the proper cleaning chemical for the job. Always follow the dilution instructions on the chemical container label. NOTE:
EcoFlex machines can either be used conventionally with detergent mixed in the tank or the detergent dispensing system can be used. When
using the detergent dispensing do not mix detergent in the tank, plain water should be used.
CAUTION!
Use only low-foaming, non-fl ammable liquid detergents intended for machine application. Water temperature should not exceed 130
degrees Fahrenheit (54.4 degrees Celsius)

SQUEEGEE INSTALLATION

1
See Figure 5. Slide the Squeegee Assembly (12) onto the squeegee mount bracket and tighten the Squeegee Mount Thumb Nuts (22).
2
Connect the Recovery Hose (16) to the squeegee inlet.
3
Lower the squeegee, move the machine ahead slightly and adjust the squeegee tilt using the Squeegee Adjustment Knob (23) so that the
rear squeegee blade touches the fl oor evenly across its entire width and is bent over slightly as shown.
FIGURE 5
FORM NO. - 56041820 - SC750, SC800, SC750 ST, SC800 ST - A-15
ENGLISH / A-15