Installation: 42Vmc028N - 036N - 048N - Carrier 42VMC---N Installation Manual

Table of Contents

Advertisement

42VMC---N
Installation: 42VMC 028N - 036N - 048N
Ceiling installation
(42VMC 028N - 048N)
Minimum 100 mm
Outdoor Sensor
Cable
Electrical
Cable
Preparation
• The piping connecting the indoor and outdoor units can be
routed in one of two directions, as shown in figure.
• If the piping is routed horizontally (direction no.
cover at the bottom of the air conditioner must be removed.
• If the piping is routed vertically (direction no.
must be installed for drainage (supplied separately, by request).
Bracket screws
Anchor screws
GB - 8
Installation
• To assemble the ceiling bracket, use the 4 mounting strips and
the 8 UNC-10 screws and nuts, as shown in figure.
• Fasten the ceiling bracket to the ceiling using the 6 anchor
screws, as shown in figure.
• The location of the ceiling bracket should allow a minimum gap
between the indoor unit and nearby walls, as shown on page 2.
Note:
The anchor screws provided are intended for use with concrete
ceilings.
Use fasteners which are appropriate for the type of ceiling
present at the installation site.
Refrigerant
Lines
• Use the template supplied, and drill the 6 fixing holes in the wall.
Use the 6 dowels provided.
Drainage
Tube
), the pipe
), a water pump
Template mod. 028N - 048N
900
28
Ø 80
3
4
509
1042
5
Frame
Outdoor air intake
Hole for refrigerant pipe