HOW TO ASSEMBLE YOUR CLEANER A) HANDLE ASSEMBLY / HOSE ASSEMBLY / MAINS LEAD STORAGE Tape Connection Pipe Hook Crevice Suction Inlet Mini Turbine Nozzle Remove tape and Insert the base of Insert the connection screw from the the handle into the pipe to suction inlet.
MAINTAINING THE HEPA FILTER UNIT Check HEPA filter unit frequently and clean when dirty. Remove HEPA filter unit from dust bin by pulling both buckle as shown. Pull to release Pull to release Clean HEPA filter unit by gently tapping over a rubbish container. Tap on several sides to ensure best cleaning.
REPLACING HEPA EXHAUST FILTER The HEPA exhaust filter removes dirt from exhaust air. Buckle Check HEPA exhaust filter after emptying dust bin. Replace when dirty. Lay down the vacuum cleaner as shown. To remove filter cover, slide upwards the buckle as shown. By holding the filter cover as shown, pull it out towards you.
THERMAL PROTECTOR This vacuum cleaner has a thermal protector which automatically trips to protect the vacuum cleaner from overheating. If a clog prevents the normal flow of air to the motor, the thermal protector trips and turns the motor off automatically. This allows the motor to cool in order to prevent possible damage to the vacuum cleaner.
Loop new belt around motor shaft and beater bar belt groove. Reinstall beater bar by inserting the end cap of the beater bar to the slot for both side. After reinstalling the beater bar, turn it by hand to make sure that the belt is not twisted of pinched and that all rotating parts turn freely.
REPLACING MOTOR ASSY AND OVERLOAD PROTECTOR - Following step replacing belt and Beater bar unit. - Loosen 3 screw from the Lower plate. - Remove the 1 screw from the Pedal shaft to detach the Pedal. - Pull out the pedal shaft slightly. - Loosen 3 screw at the frame and remove together.
Page 8
- Trun back the set. - Open the cover of Floor nozzle upper. - Pull the Nozzle hose from the Extention wand holder. OVERLOAD PROTECTOR - Take out the Floor nozzle upper and remove nicely. - Can see the Overload protector and Motor cap. - Loose 4 screw at Motor cap and remove.
REPLACING FAN MOTOR UNIT, CAPACITOR AND FUSE ASSY IMPORTANT : Before replacing any part always DISCONNECT FROM THE ELECTRICITY SUPPLY. - Pull out the Handle from Body assy and move up the Dust compartment assy. - Turn back the set. - Loosen 2 screw at the Rear body assy.
Page 10
- Make sure all the part place before dismantle or change to new part. - Location of Safety part. - Pull out the connector Capacitor from Fan Motor unit. - Pull out the connector wire from Fan motor unit. - After that move up the Fan motor unit. - Make sure the wire colour before pull out the connector wire from the Switch.
REPLACING ON/OFF SWITCH IMPORTANT : Before replacing any part always DISCONNECT FROM THE ELECTRICITY SUPPLY. - Loosen 3 screw back the set at Handle. - Open the Handle. - Turn back the set. - Please make sure wire connection and wire colour connect to Switch.
TROUBLE SHOOTING GUIDE CHECKPOINT CONDITION METHOD OF INSPECTION CAUSE / REMEDY Motor fails to rotate Plug (fuse-link) Check fuse continuity. If there is no continuity, replace it. (UK, Ireland only) (no noise is heard at all). Power cord. Check power cord continuity. If there is no continuity, replace it.
PACKING INSTRUCTIONS Operating Instructions Guarantee PACKING LIST REF. NO. PART NAME PART NO. MODEL REMARKS MC-UL592 MC-UL594 CUSHION A YMV69Z95000 ATTACHMENT PART CASE YMC54Z95000 CUSHION B YMV70Z95000 CUSHION C YMV0TZ95000 INSTRUCTION BOOK YMV01Z95000 POS LABEL YMV29T95008 POS LABEL YMV29T96008 INDIVIDUAL CARTON...