MODEL P6BO/2 TECHNICAL DETAILS
MAINTENANCE AND SERVICE
CLEANING THE APPLIANCE
It will be found that it takes less time and effort to clean the oven every time it has been
used, particularly whilst still warm before grease and spillage s are burnt on. Proprietary
oven cleaners must be used with care
damage to surfaces and components. The stainless outer panels require a wipe down
with warm soapy water. Do not use scouring pads.

FAULT FINDING

FAULT
BURNERS WILL NOT
STAY ALIGHT
BURNER GOES OUT
WHEN TURNED LOW
IRREGULAR FLAME
OVEN
FAILURE TO IGNITE
BURNER FAILS ON
LOW RATE
SERVICE (44) 01332 875665
SERVICE (44) 01332 875536
POSSIBLE CAUSE
FAULTY CONNECTION
AT THERMOCOUPLE-VALVE.
INCORRECTLY LOCATED.
BLOCKAGE IN TAP
BURNER RING, CAP NOT
CORRECTLY LOCATED
LOW PRESSURE.
DIRT OR GREASE
BROKEN OR LOOSE
CONNECTION
INCORRECT SPARK GAP
LOOSE THERMOCOUPLE
FAULTY MAGNET IN F.F.D.
THERMOCOUPLE OUT OF
POSITION.
INSTRUCTION REF: IN104
ISSUE No.
2
DATE 10.04.06
Page 5 of 15
they are highly corrosive and may cause
REMEDY
REMAKE CONNECTION
REPOSITION
THERMOCOUPLE
CLEAN AND REGREASE
RELOCATE
CHECK PRESSURE
AT TEST POINT.
CLEAN
RECONNECT/REPLACE
H.T.LEAD
SET GAP 3-4MM
REPLACE
REPLACE
THERMOSTAT
REPOSITION