Download Print this page

PARRY P6BO Installation Instructions Manual page 6

Advertisement

TELEPHONE:
FAX:
MODEL P6BO/2 TECHNICAL DETAILS
FLOW TEST SEQU 2
HOB BURNER
NAT
G20
PRESSURE
20mbar
INJECTOR
1.75mm
GAS RATE
0.530m3/hr
HEAT INPUT
5.77KW
OVEN
INJECTOR
2 x 1.50mm
GAS RATE
0.760m3/hr
HEAT INPUT
8.27 KW
TOTAL HEAT INPUT NATURAL GAS
TOTAL HEAT INPUT BUTANE
TOTAL HEAT INPUT PROPANE
LOW RATE ADJUSTER SCREW
OVEN BYPASS ADJUSTER SCREW
LOW RATE ADJUSTER SCREW
OVEN BYPASS ADJUSTER SCREW
Gas connections ½ B.S.P.T. at left hand rear of appliance incorporating pressure test
point.
Oven size 750mm wide x 600 deep x 475mm high = volume 0.2M3 (7.4ft3)
Appliance Total Weight 135 kg.
L.P.G. Conversion kit is available for this appliance and should be fitted by a qualified
engineer if required. (See L.P.G. Conversion instructions)
On conversion to G25 the oven burner is fitted with an Air Restricter. This is available
from PARRY Group Ltd.
TEST 3 HOB FLOW RATE HIGH =
TEST 4 HOB FLOW RATE LOW =
TEST 5 OVEN FLOW RATE
TESTS 3 AND 4 ALO APPLY TO ALL PARAGON AND ALPHA HOB UNITS.
L.P.G. SEQU 6 HOB HIGH .190 LOW .034 OVEN .318
SERVICE (44) 01332 875665
SERVICE (44) 01332 875536
L.P.G.
G30
28mbar
1.07mm
0.163m2/hr
4.84KW
2 x .99mm
0.250m3/hr
7.90 KW
=
INSTRUCTION REF: IN104
ISSUE No.
DATE 10.04.06
Page 6 of 15
G31
G25
37mbar
20mbar
1.07mm
1.80mm
0.20m/2hr
0.65m3/hr
4.84KW
5.87KW
2 x .99mm
2 x 1.5mm
0.320m3/hr
0.87m3/hr
7.90KW
7.9KW
G20/25
42.89KW
G30
42.05KW
G31
40.06KW
G20/25
SIZE 84
G20/25
SIZE 95
G30/31
SIZE 50
G30/31
SIZE 55
.530 M³/HR
.110 M³/HR
.760 M³/HR
2
G25
5mbar
1.75mm
0.65m3/hr
5.87KW
2 x 1.5mm
0.9mm3/hr
8.22KW

Advertisement

loading

This manual is also suitable for:

P6b2