L Technical Data; General - Vaillant flexoTHERM exclusive VWF 57/4 Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

L
Technical data
L.1

General

Dimensions
Product dimensions, height, without ad-
justable feet
Product dimensions, width
Product dimensions, depth
Weight, with packaging
Weight, without packaging
Weight, ready for operation
Electrics
Compressor/heating circuit/control circuit
rated voltage
Auxiliary heater rated voltage
Power factor
Power factor for the auxiliary heater
Required network impedance Z
in-rush current limiter
Required network impedance Z
auxiliary heater
Fuse type, characteristic C, slow-blow,
three-pole switching (disconnection of
the three mains connection lines in one
switching operation)
Optional on-site residual-current circuit
breaker
In-rush current with in-rush current lim-
iter
Measuring current L1 for compressor and
electronics (connection diagram 1)
Measuring current L1 for the compressor
and electronics plus maximum 1.3 A at
X12 VR 40, maximum 0.9 A at X14 circu-
lation pump and maximum 2.5 A at TB
X141, X143, X144 and X145 (connection
diagram 1)
Measuring current L1 & L2 for
compressor and electronics (L1 = L2)
(connection diagram 2)
Measuring current L1 & L2 for the com-
pressor and electronics plus maximum
1.3 A at X12 VR 40, maximum 0.9 A at X14
circulation pump and maximum 2.5 A at
TB X141, X143, X144 and X145 (L1 = L2)
(connection diagram 2)
Min. electrical power consumption of
compressor
Max. electrical power consumption of
compressor
0020213395_00 flexoTHERM exclusive Installation and maintenance instructions
VWF 57/4 230 V
1,183 mm
595 mm
600 mm
161 kg
151 kg
157 kg
VWF 57/4 230 V
1~/N/PE 230 V 50 Hz
2~/PE 230 V 50 Hz
1~/N/PE 230 V 50 Hz
3~/PE 230 V 50 Hz
cos φ = 0.75 – 0.9
cos φ = 1
≤ 0.472 Ω
with
max
≤ 0.472 Ω
for
max
Designing in accordance
with the selected
connection diagrams
RCCB type A (type A
pulse-current-sensitive
residual-current circuit
breakers) or RCCB type B
(type B universal-current-
sensitive residual-current
circuit breakers)
≤ 15 A
11.9 A
16.6 A
11.9 A
16.6 A
1.40 kW
2.10 kW
VWF 87/4 230 V
1,183 mm
595 mm
600 mm
176 kg
166 kg
173 kg
VWF 87/4 230 V
1~/N/PE 230 V 50 Hz
2~/PE 230 V 50 Hz
1~/N/PE 230 V 50 Hz
3~/PE 230 V 50 Hz
cos φ = 0.75 – 0.9
cos φ = 1
≤ 0.472 Ω
≤ 0.472 Ω
Designing in accordance
with the selected
connection diagrams
RCCB type A (type A
pulse-current-sensitive
residual-current circuit
breakers) or RCCB type B
(type B universal-current-
sensitive residual-current
circuit breakers)
≤ 19 A
19.1 A
23.8 A
19.1 A
23.8 A
2.10 kW
3.10 kW
Appendix
VWF 117/4 230 V
1,183 mm
595 mm
600 mm
188 kg
178 kg
185 kg
VWF 117/4 230 V
1~/N/PE 230 V 50 Hz
2~/PE 230 V 50 Hz
1~/N/PE 230 V 50 Hz
3~/PE 230 V 50 Hz
cos φ = 0.75 – 0.9
cos φ = 1
≤ 0.472 Ω
≤ 0.472 Ω
Designing in accordance
with the selected
connection diagrams
RCCB type A (type A
pulse-current-sensitive
residual-current circuit
breakers) or RCCB type B
(type B universal-current-
sensitive residual-current
circuit breakers)
≤ 60 A
24.9 A
29.6 A
24.9 A
29.6 A
2.60 kW
4.10 kW
59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents