E Fault Codes - Vaillant flexoTHERM exclusive VWF 57/4 Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

Status code
Meaning
S.350
Heating rod: Safety cut-out open
S.351
Heating rod: Flow temp. too high
S.352
Heating rod: Pressure too low
S.353
Heating rod: Flow rate too low
S.354
Heating rod: Phase failure
E
Fault codes
Note
In the event of rare faults which are caused by components in the refrigeration circuit, inform Customer Service.
Code
Meaning
F.070
Invalid Device Specific Number
F.086
Building circuit: Lockout contact
S20 open
F.514
Temp. sensor fault: Compressor
inlet
F.517
Temp. sensor fault: Compressor
outlet
F.519
Sensor fault: Building circuit re-
turn temp.
F.520
Temp. sensor fault: Building cir-
cuit flow
F.532
Building circuit: Flow rate too low
F.546
Sensor fault: High pressure
F.583
Building circuit: Flow temp. too
low
F.685
Connection error: Control not de-
tected
F.701
Temp. sensor fault: Environ. cir-
cuit inlet
0020213395_00 flexoTHERM exclusive Installation and maintenance instructions
Cause
Replacing the control PCB and
display PCB
Contact S20 on heat pump mains
connection PCB (HMU) open
Incorrect setting of the limit thermo-
stat
Flow temperature sensor (heat
pump, gas-fired boiler, system
sensor) measures values that
deviate downwards
Sensor not connected or sensor in-
put has short-circuited
Sensor not connected or sensor in-
put has short-circuited
Sensor not connected or sensor in-
put has short-circuited
Sensor not connected or sensor in-
put has short-circuited
Stop cock was not opened
Building circuit pump defective
All consumers in the heating system
are closed
Flow rate is too low for recording
with the volume flow sensor
(< 120 l/h)
Sensor not connected or sensor in-
put has short-circuited
Four-way valve is mechanically
blocked
The temperature sensor in the flow is
defective
Air in the building circuit
System controller was previously de-
tected but the connection is broken
Sensor not connected or sensor in-
put has short-circuited
Appendix
Remedy
Setting the correct Device Specific
Number
Adjust the maximum flow temperat-
ure for the direct heating circuit via
the system controller (observe the
upper switch-off threshold for the
boilers)
Adjust the set value for the limit ther-
mostat
Check the sensor values
Check the sensor, and replace if
necessary
Replace the cable harness
Check the sensor, and replace if
necessary
Replace the cable harness
Check the sensor, and replace if
necessary
Replace the cable harness
Check the sensor, and replace if
necessary
Replace the cable harness
Check the stop cocks and thermo-
static radiator valves
Ensure that the flow rate is at least
35% of the nominal flow rate
Check that the building circuit pump
functions correctly
Check the sensor (e.g. using an in-
stallation aid), and replace if neces-
sary
Replace the cable harness
Check the building circuit flow rate
Check the quality of the plug contact
on the PCB and on the cable har-
ness
Check that the sensor is working
correctly (measure resistance using
sensor characteristic values)
Replace the sensor
Purging the building circuit
Check the eBUS connection to the
system controller
Check the sensor, and replace if
necessary
Replace the cable harness
43