Setting The Flow Temperature In Heating Mode (With No Controller Connected); Setting The Flow Temperature In Cooling Mode (With No Controller Connected); Handing The Product Over To The Operator; 11 Troubleshooting - Vaillant flexoTHERM exclusive VWF 57/4 Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

11 Troubleshooting

3
Groundwater heat
source
A
Remaining feed head in
hPa (mbar)
10.2.4.2 Remaining feed head for VWF 8x/4
environment circuit pump at nominal flow
A
800
700
600
1
500
400
300
200
100
0
40
50
60
1
Air heat source
2
Ground heat source
3
Groundwater heat
source
10.2.4.3 Remaining feed head for VWF 11x/4
environment circuit pump at nominal flow
A
800
2
700
1
600
500
400
300
200
100
0
40
50
60
1
Air heat source
2
Ground heat source
3
Groundwater heat
source
32
B
Pump output in %
2
3
70
80
90
100
A
Remaining feed head in
hPa (mbar)
B
Pump output in %
3
70
80
90
100
A
Remaining feed head in
hPa (mbar)
B
Pump output in %
Installation and maintenance instructions flexoTHERM exclusive 0020213395_00
10.3
Setting the flow temperature in heating
mode (with no controller connected)
1.
Activate manual mode.
Menu → Installer level → Configuration → Enable
limp home mode
2.
Press
( ).
The display shows the flow temperature in heating
mode.
3.
Change the flow temperature in heating mode by press-
ing
or
.
Max. heating mode target flow temperature: 75 ℃
4.
Confirm this change by pressing
10.4
Setting the flow temperature in cooling
mode (with no controller connected)
1.
Activate manual mode.
Menu → Installer level → Configuration → Enable
B
limp home mode
2.
Press
twice.
The display shows the value of the flow temperature
in cooling mode.
3.
Change the flow temperature in cooling mode by press-
ing
or
.
4.
Confirm this change by pressing
Note
At the factory, the target flow temperature
can be set to between 20 °C and 16 °C in
passive cooling mode.
10.5

Handing the product over to the operator

Explain to the operator how the safety devices work and
where they are located.
Inform the operator how to handle the product.
In particular, draw attention to the safety information
which the operator must follow.
Inform the operator of the necessity to have the product
maintained according to the specified intervals.
B
Pass all of the instructions and documentation for the
product to the operator for safe-keeping.
11 Troubleshooting
11.1
Displaying the Live Monitor (current
product status)
Menu → Live Monitor
You can use the Live Monitor to display the current status
of the product.
Status codes – Overview (→ Page 41)
(OK).
(OK).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents