5 Installation

5
Installation
5.1

Checking the scope of delivery

1.
Carefully remove the packaging and padding without
damaging the parts of the product.
2.
Check that the scope of delivery is complete.
Quantity
Description
1
Heat pump
1
Installation set comprising
3 x flat seal (yellow/green) for heating
circuit
1 x 3/4" flat seal for the heating expansion
vessel connection
2 x O-ring seals for brine circuit
1
Expansion relief valve for brine circuit, 1/2",
3 bar
1
Enclosed documentation
5.2

Selecting the installation site

Select a dry room that is frost-proof throughout and in
which the permissible ambient temperature is neither
above nor below the permitted range.
Permissible ambient temperature: 7 ... 25 ℃
Permissible relative air humidity: 40 ... 75 %
Ensure that the installation room has the required min-
imum volume.
Heat pump
R 410 A refri-
gerant filling
volume
VWF 57/4 230V
1.50 kg
VWF 87/4 230V
2.40 kg
VWF 117/4 230V
2.50 kg
Ensure that the required minimum clearances can be
maintained.
When selecting the installation site, you must take into
consideration that when the heat pump is in operation, it
will transfer vibrations to the floor and the nearby walls.
Ensure that the floor is level and has sufficient load-bear-
ing capacity to bear the weight of the heat pump and a
domestic hot water cylinder.
Ensure that cables can be easily routed (for brine, hot
water and heating).
12
Minimum in-
stallation room
volume
3.41 m³
5.45 m³
5.68 m³
Installation and maintenance instructions flexoTHERM exclusive 0020213395_00