Removing The Casing Top And Side Casings; Removing The Refrigeration Circuit Cover - Vaillant flexoTHERM exclusive VWF 57/4 Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

5 Installation
A
B
3.
Pull each part of the front casing forwards slightly and
remove it by lifting it upwards.
5.9

Removing the casing top and side casings

1.
Pull the casing top forwards slightly and remove it by
lifting it upwards.
16
2.
To remove a side casing, remove the four screws at the
front and the three screws at the back.
3.
Remove the side casing.
5.10

Removing the refrigeration circuit cover

A
B
1.
Remove the four screws.
2.
Pull the top of the refrigeration circuit cover forwards
and lift it out of the guide.
Installation and maintenance instructions flexoTHERM exclusive 0020213395_00
B
B
A
A