5.3 Value of Thermistor room temperature sensor
R25℃=5KΩ±1%
B25 /50
℃=3450K±1%
Temp.(℃)
-20
-19
-18
-17
-16
-15
-14
-13
-12
-11
-10
-9
-8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Haier air conditioner
Max.(KΩ)
Normal(KΩ)
38.5398
37.3992
36.5922
35.5274
34.7549
33.7607
33.0211
32.0927
31.3843
30.5172
29.8385
29.0286
28.3782
27.6216
26.9981
26.2913
25.6934
25.0330
24.4595
23.8424
23.2922
22.7155
22.1875
21.6486
21.1417
20.6380
20.1513
19.6806
19.2131
18.7732
18.3241
17.9129
17.4813
17.0970
16.6822
16.3230
15.9242
15.5886
15.2050
14.8913
14.5224
14.2293
13.8757
13.6017
13.2617
13.0057
12.6786
12.4393
12.1247
11.9011
11.5983
11.3894
11.0979
10.9028
10.6221
10.4399
10.1696
9.9995
9.7390
9.5802
9.3292
9.1810
8.9391
8.8008
8.5676
8.4385
8.2137
8.0934
Min.(KΩ)
36.2887
34.4900
32.7916
31.1872
29.6710
28.2377
26.8824
25.6003
24.3870
23.2384
22.1508
21.1205
20.1443
19.2189
18.3414
17.5092
16.7195
15.9700
15.2585
14.5827
13.9408
13.3320
12.7534
12.2035
11.6806
11.1833
10.7102
10.2599
9.8313
9.4231
9.0343
8.6638
8.3107
7.9740
- 10 -
Edition: 20070925
Tolerance(℃)
-1.78
1.62
-1.76
1.60
-1.74
1.59
-1.72
1.57
-1.70
1.56
-1.68
1.54
-1.66
1.53
-1.64
1.51
-1.62
1.49
-1.60
1.48
-1.58
1.46
-1.56
1.44
-1.53
1.43
-1.51
1.41
-1.49
1.39
-1.47
1.38
-1.45
1.36
-1.43
1.34
-1.40
1.32
-1.38
1.30
-1.36
1.29
-1.34
1.27
-1.31
1.25
-1.29
1.23
-1.27
1.21
-1.24
1.19
-1.22
1.17
-1.20
1.15
-1.17
1.13
-1.15
1.11
-1.13
1.09
-1.10
1.07
-1.08
1.04
-1.05
1.02