Camera ID Setup
ON
ON
1
2
3
4
5
ID number of camera is set using binary number. The example is shown bellow.
DIP1
Pin
1
ID Value
1
Default
on
ex) ID=10
off
The range of ID is 1~255. Do not use 0 as camera ID. Factory default of Camera ID is 1.
If you want to control a certain camera, you must match the camera ID with Cam ID setting of DVR or
Controller.
Communication Protocol Setup
Select the appropriate Protocol with DIP switch combination.
DIP2
Pin
1
RS485
ID Value
Termination
Default
Off
Pin1 is used for RS485, 100W termination. Set ON DIP2‐1st of only the last looped camera from the
controller. Even in case of only one camera, set ON DIP2‐1st of the camera.
Pin3
Pin4
OFF
OFF
ON
ON
ON
OFF
Pin7
Pin8
OFF
OFF
OFF
ON
ON
OFF
ON
ON
6
7
8
2
3
2
4
off
off
on
off
2
3
Not
Protocol1
Protocol 2
used
Off
Off
CAM 1
CAM 2
CAM n-1
Protocol
Pelco‐D or Pelco‐P
Not used
Maxpro
BAUD RATE
Not Used
2400bps (Pelco‐D)
4800bps (Pelco‐P)
9600bps (Maxpro)
4
5
8
16
off
off
on
off
4
5
6
Not
Not
used
used
Off
Off
Off
TERMINATION
CAM n
NM‐IP4500
6
7
8
32
64
128
off
off
off
off
off
off
7
8
Baud Rate 1
Baud Rate 2
Off
On
16