Installation

Forming the Piping

In cases where the outdoor unit is
installed below the indoor unit
perform the following.
1. Tape the piping, drain hose and connecting cable
from down to up.
2. Secure the tapped piping along the exterior wall
using saddle or equivalent.
In cases where the Outdoor unit is
installed above the Indoor unit
perform the following.
1. Tape the piping and connecting cable from down to
up.
2. Secure the taped piping along the exterior wall.
Form a trap to prevent water entering the room.
3. Fix the piping onto the wall using saddle or
equivalent.
76
Seal small openings
around pipings with a
gum type sealant.
Trap is required to prevent water
from entering into electrical parts.
Inverter Single
Inverter Single
Inverter Single
Inverter Single
Connecting cable
(Conduit)
Saddle
Pipings
Drain hose
Seal a small opening
around the pipings
with gum type sealant.
Trap
Trap
6RMI0-02A
Taping

Hide quick links: