Capacity tables
AS-W123ERH1(LA126HV)
Indoor Air
Temperature
WB°C(°F) DB°C(°F)
TC
14(57.2)
20(68)
3.39
16(60.8) 22(71.6)
3.60
18(64.4)
25(77)
3.81
19(66.2) 27(80.6)
3.91
22(71.6)
30(86)
4.23
24(75.2) 32(89.6)
4.44
Indoor Air
Temperature
WB°C(°F) DB°C(°F)
TC
14(57.2)
20(68)
2.82
16(60.8) 22(71.6)
3.03
18(64.4)
25(77)
3.24
19(66.2) 27(80.6)
3.34
22(71.6)
30(86)
3.65
24(75.2) 32(89.6)
3.85
AS-W1838RH1(LA186HV)
Indoor Air
Temperature
WB°C(°F) DB°C(°F)
TC
14(57.2)
20(68)
5.06
16(60.8) 22(71.6)
5.37
18(64.4)
25(77)
5.68
19(66.2) 27(80.6)
5.84
22(71.6)
30(86)
6.31
24(75.2) 32(89.6)
6.62
Indoor Air
Temperature
WB°C(°F) DB°C(°F)
TC
14(57.2)
20(68)
4.21
16(60.8) 22(71.6)
4.52
18(64.4)
25(77)
4.83
19(66.2) 27(80.6)
4.98
22(71.6)
30(86)
5.44
24(75.2) 32(89.6)
5.75
Symbol
AFR : Air flow rate
DB : Dry bulb temperature
WB : Wet bulb temperature
TC : Total capacity
SHC : Sensible capacity
PI : Power Input
(Comp.+ indoor fan motor+outdoor fan motor)
40
20(68)
SHC
PI
TC
2.37
0.64
3.25
2.33
0.87
3.45
2.28
0.94
3.66
2.28
0.95
3.76
2.15
0.95
4.08
2.09
0.94
4.28
40(104)
SHC
PI
2.48
1.10
2.44
1.19
2.38
1.20
2.38
1.21
2.24
1.23
2.18
1.25
20(68)
SHC
PI
TC
3.84
1.00
4.84
3.78
1.36
5.15
3.69
1.47
5.46
3.68
1.48
5.61
3.48
1.48
6.08
3.38
1.47
6.39
40(104)
SHC
PI
4.01
1.72
3.94
1.85
3.86
1.88
3.85
1.88
3.63
1.91
3.53
1.95
[m
3
/min]
[°C]
[°C]
[kW]
[kW]
[kW]
Inverter Single
Inverter Single
Outdoor Air Temperature : DB°C(℉)
25(77)
SHC
PI
TC
2.40
0.67
3.05
2.36
0.88
3.25
2.31
0.94
3.46
2.30
0.96
3.56
2.17
0.97
3.87
2.11
0.98
4.08
Outdoor Air Temperature : DB°C(℉)
43(109.4)
TC
SHC
2.75
2.51
2.95
2.48
3.16
2.42
3.26
2.42
3.57
2.28
3.78
2.21
Outdoor Air Temperature : DB°C(℉)
25(77)
SHC
PI
TC
3.89
1.04
4.54
3.82
1.37
4.85
3.74
1.47
5.16
3.73
1.50
5.31
3.52
1.52
5.78
3.42
1.53
6.09
Outdoor Air Temperature : DB°C(℉)
43(109.4)
TC
SHC
4.10
4.06
4.40
4.01
4.71
3.92
4.86
3.91
5.32
3.69
5.63
3.59
Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates nominal maximum capacity.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.
32(89.6)
SHC
PI
TC
2.45
0.90
2.95
2.41
1.06
3.16
2.36
1.11
3.37
2.35
1.13
3.46
2.22
1.15
3.78
2.16
1.17
3.98
46(114.8)
PI
TC
SHC
1.08
2.67
2.52
1.13
2.87
2.48
1.13
3.08
2.43
1.13
3.18
2.42
1.14
3.49
2.29
1.16
3.70
2.22
32(89.6)
SHC
PI
TC
3.97
1.40
4.41
3.90
1.65
4.71
3.82
1.74
5.02
3.81
1.76
5.16
3.60
1.80
5.63
3.49
1.83
5.94
46(114.8)
PI
TC
SHC
1.68
3.98
4.09
1.76
4.29
4.02
1.76
4.59
3.93
1.76
4.75
3.92
1.77
5.21
3.70
1.81
5.52
3.59
6RMI0-02A
35(95)
SHC
PI
2.49
1.00
2.45
1.14
2.40
1.18
2.39
1.16
2.26
1.22
2.19
1.24
PI
0.97
0.98
0.96
0.95
0.95
0.97
35(95)
SHC
PI
4.04
1.56
3.97
1.78
3.88
1.84
3.87
1.81
3.65
1.90
3.55
1.94
PI
1.51
1.53
1.49
1.48
1.48
1.52