Download Print this page

Correcting Malfunctions - BRAVILOR BONAMAT RLX series Instruction Manual

Hide thumbs Also See for RLX series:

Advertisement

1.7

Correcting malfunctions

D See §1.6.1 of the "General user instructions".
1.7.1
Malfunctioning analysis hot–water module
Symptom:
1. On the display, '00' is
flashing constantly.
2. When switching on the
module, the display will light
up and immediately
afterwards will go off.
3. Descaling signal is flashing.
4. Descaling signal is still
flashing.
5. The water temperature is
too low or too high.
1.7.2
Display messages
Possible cause:
E1
The overflow protection was activated.
E2
Temperature sensor is loose or broken.
4
version
1.0
LIST OF MALFUNCTIONS
Possible cause:
The machine will start up the
boiling programme.
The boiling programme is
interrupted.
Descaling counter has reached
the maximum number of litres.
The counter has not been reset
after running the descaling
procedure.
During programming, the
temperature has been set too
high or loo low.
DISPLAY MESSAGES
Check the supply hose for any kinks.
Check the water pressure at the same time.
Reset the system afterwards: set the
ON/OFF switch to the off position and then
switch it on again.
Call in service.
Switch the ON/OFF switch off.
Call in service.
Actions:
Wait until the boiling programme
is finished.
Wait until the temperature in the
kettle has gone down, to below
50_C.
Run the descaling sequence on
the module, see §1.6.2.
Reset the descaling counter,
see §1.6.2 item 29.
Adjust the set water
temperature, see §1.5.
Actions:
ECopyright Bravilor Bonamat B.V.

Advertisement

loading