Download Print this page

Maintenance General - BRAVILOR BONAMAT RLX series Instruction Manual

Hide thumbs Also See for RLX series:

Advertisement

1.6
Maintenance
1.6.1
General
D See § 1.5 of the "General user instructions".
1.6.2
Descaling
WARNING
n Always wear gloves and protective facial gear
during the descaling procedure.
n Remain near the machine during the
descaling process.
1. First read the "General user instructions"
§ 1.5.3.
2. Make sure there is a sufficiently large
container (min. 5 litres) to collect the liquid.
3. Switch off the module.
4. Drain off the water using the hot water
draw– off tap.
5. Remove the plug from the pouring opening
(2.).
6. Pour in cold water (1 litre) through the
pouring– in opening of the module, using the
funnel.
7. Drain off the water using the hot water
draw– off tap.
8. Dissolve 100 gr. of Renegite in a
water (40_C).
9. Carefully pour the Renegite solution into the
pouring opening, using a funnel.
10. Seal off the pouring opening with the plug.
11. Switch on the module.
12. Wait until the water is heated up (the indicator
on the display will stop flashing).
13. Switch off the module.
14. Remove the plug from the pouring opening
(2.).
ECopyright Bravilor Bonamat B.V.
15. Draw off 4 cups of Renegite solution and
pour back into the pouring opening, using the
funnel.
16. Now wait approx. 5 minutes.
17. Seal off the pouring opening with the plug.
18. Switch on the module.
19. Every minute (3 times in total) draw off 4 cups
of Renegite solution via the draw– off tap.
20. Switch off the module.
21. Draw off as much Renegite solution as
possible using the draw– off tap.
WARNING
n The water can be very hot.
22. Draw off the remainder of the Renegite
solution using the special drain– off tap
(located behind the drip– tray).
23. Place the plug back on the drain.
24. Switch on the module.
25. Wait for 10 minutes.
1
/
litre of
2
26. Repeat steps 20. through 25. twice.
27. Wait until the water is heated up (the indicator
on the display will stop flashing).
28. Draw off approx. 1 litre of water using the
draw– off tap, so that the draw– off tap is
rinsed thoroughly.
29. Press the [–] button (B.) for 30 seconds to
reset the descaling signal to zero.
Î Î
3
version
1.0

Advertisement

loading