1.
MODULES 3 AND 7 (HOT WATER)
1.1
Introduction
In this document, the specific information for
the above–mentioned module is discussed.
Please also thoroughly read the general user
instructions.
1.1.1

General description

These modules are designed for the preparation
of hot water. As soon as the module is switched
on using the ON/OFF switch, the water will be
heated. The water is drawn off using the draw–off
tap.
1.1.2
Main components
1
2
3
4
5
Fig. 1 Main components hot–water modules
1. ON/OFF switch
2.
operating panel
3.
pouring opening descaler
4. draw–off tap
5. condensation outlet
ECopyright Bravilor Bonamat B.V.
1
2
3
1.2

Technical data

D See table 1 for additional technical information
about the hot–water modules.
Boiler capacity
hourly capacity
water reserve
Table 1 Technical information
1.3

First use

The hot–water module will automatically run a
boiling programme to determine the boiling
point of the water. This only happens when the
machine is put into operation for the first time.
This is necessary because the boiling point
depends on the local atmospheric pressure. For
example, the boiling point at sea–level will be
approx. 100_C, whereas at a height of 2.000 m
the boiling point might be as low as 97_C.
During the determination of the boiling point, the
display will show '00'.
After switching on the mains voltage, the water in
the boiler will be heated to the maximum
temperature that can be reached (this is the
temperature at which the water is boiling). The
temperature of the boiling point is now recorded
in the machine.
1.3.1
Flushing
1. Switch on the module.
– Wait until the boiling programme is finished.
2. Drain the reservoir completely using the
draw–off tap.
The module is now ready for use.
Modules 3 and 7
44,7
litre
18,7
litre
41,7 litre
1
version
1.0