Electrical connections

All field electrical connections are the responsibility of the installer.
WARNING
Make water connections before electrical connections.
Make ground connection prior to any other electrical connections
Unità
Allowable Voltage Range
Maximum power drawn
Maximum current drawn
Type
Fuses
Current
External circulation
Use cables H03VV-F 4x0.75 mm2 to connect the control to wire NUI (33AW-CS1)
and H03VV-F 6x0.75 mm2 to connect the control to wire SUI (33AW-RC1)
Also check the supply voltage and frequency of the indoor unit.
Remove the front panel, the electric parts appear at the
front side.
The power supply cables can be inserted into the pipe
sold on the market so that they do not make contact with
the compressor and the hot pipes.
To ensure good tensile strength, the electric cables must be
fastened using the cable-holder on the plate.
(Only for size 015 use the strain relief supplied with the unit)
The unit can be controlled and set via:
User Comfort Interface wire control 33AW-CS1 (Optional)
Wire remote control 33AW-RC1 (Optional)
Switches (not supplied)
For the electrical connections refer to Figure 17, while, for
use, refer to the relative manuals.
Wired control
For installation of wired remote controller please refer to the control installation manual.
Size the cable, the cables must be H07 RN-F type (3x2,5 mm
According to the installation instructions, all devices for disconnection from the power supply
mains must have a contact opening (4 mm) to allow total disconnection according to the conditions
provided for the overvoltage class III.
To prevent any risk, the power cable must only be replaced by the technicians of the after-sales
service.
8
30AWH
004_
V- ph - Hz
V
kW
2
A
7,2
A
10 - Type B
mm2
A
30AWH
006_
008_
230 - 1 -50
207 ÷ 254.
2,3
2,7
11
14
gL Type
15 - Type B
15 - Type B
H07RN-F 3 x 2.5mm2
2
S1: Off/ON
S2: Cooling/Heating
S3: Normal / Economic
1=3 Way valve
3=Trace Heater / Additional Water pump
4=External heat source / Defrost
5=Alarm / Ambient temperature reached
6=Limitation frequency
7=Sanitary Input
8=Alarm Input
9=External temperature probe (NTC 3kΩ@25°C)
10=External water pump
Note:
The quality of the contacts must be greater than 25mA @ 12V
2
).
(Fig. 17)
012_
015_
5,1
5,1
20
23
25 - Type D
25 - Type D