SOFTWARE CONFIGURATION STRINGS
Description
Enter Service Mode (configuration) fixed 115200 Baud rate
Exit Service Mode (configuration) return to programmed Baud rate
Apply Configuration to RAM (temporary memory) and Exit Service Mode
Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode
To configure the reader using configuration strings, you must enter Service
Mode which automatically sets the reader communication to 115200
baudrate. You must therefore set the host accordingly for RS232
communications. Upon exiting Service Mode, the programmed baud rate
NOTE
will be restored.
Description
Write Single Configuration Item to RAM (temporary memory)
Read Single Configuration Item from RAM (temporary memory)
Reset Reader
Read Application Software Release (does not require Enter/Exit Service Mode)
Host Commands Obey
Host Commands Ignore
Enable all Symbologies
Disable all Symbologies
To read a particular parameter setting from the reader, send the read
parameter command without any value. The reader will respond with its
currently configured value.
NOTE
The Read Application Software Release command is a direct command that
does not require entering Service Mode.
NOTE
Description
Restore Custom Default Configuration
RS232
USB-COM
USB-KBD
USB-KBD-ALT
USB KBD-APPLE
The Interface Selection commands store and load the new interface type
with its factory defaults into the current configuration.
NOTE
SERIAL CONFIGURATION STRINGS
ENTER/EXIT CONFIGURATION COMMANDS
CONFIGURATION COMMANDS
INTERFACE SELECTION COMMANDS
3
Command
S
s
r01
Ar
Command
Cxxxxxx
cxxxx
R
$+$!
CIFIH00
CIFIH01
AA
AD
Command
HA00
HA05
HA47
HA35
HA2B
HA2C