Main Functions
1.9.6
Self-Diagnosis Digital Display
The microcomputer continuously monitors main operating conditions of the indoor unit, outdoor
unit and the entire system. When an abnormality occur, the LCD remote controller displays error
code. These indications allow prompt maintenance operations.
1.9.7
Auto-restart Function
Even if a power failure (including one for just a moment) occurs during the operation, the
operation restarts in the condition before power failure automatically when power is restored.
(Note) It takes 3 minutes to restart the operation because the
activated.

1.10 WEEKLY TIMER

Up to 4 timer settings can be saved for each day of the week (up to 28 settings in total).
Those 3 items of "On / OFF", "temperature" and "time" can be set.
30
SiBE06-708
3-minute standby
function is
Function and Control