REMOVING THE UPPER MANIFOLD ASSEMBLY,
AND THE INLET & OUTLET BEZELS
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.
Unplug dishwasher or disconnect power.
2.
Turn off the water supply to the dish-
washer.
3.
Remove the silverware basket and dish
racks.
4.
To remove the upper manifold assem-
bly, remove the retaining screw from the
manifold assembly.
NOTE: There is an O-ring behind the up-
per manifold assembly on the inlet cap.
Be sure that it is properly in place on the
cap.
Screw
O-Ring
Inlet Cap
Upper Manifold Assembly
WARNING
Electrical Shock Hazard
5.
To remove the inlet and outlet bezels,
twist the bezels 1/4-turn counterclockwise.
NOTE: There is a filter behind the outlet
bezel (vent). Be sure it is in place before
reinstalling the bezel.
Outlet Bezel
Outlet Filter
4-5