Install The Hardware - Axis P3343-VE Installation Manual

Hide thumbs Also See for P3343-VE:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
AXIS P3343-VE/P3344-VE Installation Guide

Install the hardware

Prepare the network cable
If a cable other than the provided cable is used, you need to prepare a network cable with a gasket.
Gently force the cable through the gasket provided and attach a network connector. It may be
necessary to pierce a hole in the gasket with the resitorx screwdriver.
Note:
• Do not force the network connector into the gasket.
• Do not pierce the gasket with a knife or other sharp object.
Prepare the unit casing (routing cables along the wall)
If the cables are to be routed along the wall, prepare the unit casing as follows:
1. Detach the side lid that is attached to the unit casing by removing the screw.
2. Loosen the two screws on the cable shield and detach the bottom part.
3. Attach the bottom part of the cable shield to the unit casing with the screw.
Unit casing
Screw
Side lid
Replace clear/smoked dome cover (optional)
The AXIS P3343-VE/P3344-VE is supplied with an optional dome. To replace the dome cover:
1. Loosen the 4 screws under the dome cover that hold the dome in place.
2. Transfer the gasket from the old dome to the new.
3. Replace the old dome with the new and tighten the screws.
Cable shield
Top part
Bottom part
Page 5
Unit casing

Advertisement

Table of Contents
loading

This manual is also suitable for:

P3344-ve

Table of Contents